Schindler 3100 Owner's Manual page 153

Table of Contents

Advertisement

Schindler 3100/3300/6300
Copyright © 2017 INVENTIO AG
Code
SAFETY CHAIN KNA CONTACT OVERBRIDGING ACTIVATION
The overbridging of the safety circuit contact at the car emergency exit (for
example, used in fire operation Korea) wasn't successful.
3505
C1:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A1:Replace SIAP board
SAFETY CHAIN KNA CONTACT OVERBRIDGING LOST
The overbridging of the safety circuit contact at the car emergency exit (for
example, used in fire operation Korea) was lost.
3506
C1:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A1:Replace SIAP board
SAFETY CHAIN KNA CONTACT OVERBRIDGING DEACTIVATION
The cancellation of the overbridging of the safety circuit contact at the car
emergency exit (for example, used in fire operation Korea) wasn't successful.
3507
C1:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A1:Replace SIAP board
SAFETY CHAIN KNA CONTACT UNEXPECTED OVERBRIDGING
An unexpected overbridging of the safety circuit contact at the car emergency
exit has occurred.
3508
C1:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A1:Replace SIAP board
SAFETY CHAIN SIM DOORZONE CONTACT OVERBRIDGING
ACTIVATION UNSUCCESSFUL
The overbridging of the door safety circuit contacts, allowing to travel the car
with opened doors (for example, used in fire operation Korea) wasn't
successful.
C1:Wiring of door zone simulation bad
3509
A1:Check connections between SUET board and SIAP board
C2:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A2:Replace SIAP board
C3:Door safety circuit overbridging failed
A3:Check errors 0338 for cause and actions
SAFETY CHAIN SIM DOORZONE CONTACT OVERBRIDGING LOST
The overbridging of the door safety circuit contacts, allowing to travel the car
with opened doors (for example, used in fire operation Korea) was lost.
C1:Wiring of door zone simulation bad
A1:Check connections between SUET board and SIAP board
3510
C2:SIAP PCB defect (for example, relays simulating door zone
(PHS/PHS1) defect)
A2:Replace SIAP board
C3:Door safety circuit overbridging lost
A3:Check errors 0339 for cause and actions
EEPROM Message
J 43402603 / 01
153/269

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3100 and is the answer not in the manual?

Related Products for Schindler 3100

This manual is also suitable for:

33006300

Table of Contents

Save PDF