Carrier 33CS Installation, Service, And Troubleshooting Instructions page 7

Unitary controller thermostat
Table of Contents

Advertisement

Fig. 6 — TEMP System Thermostat
Display Screen
OPTION
CATEGORY 1.0 SET POINTS
1.1
Cooling Set Point Low Limit (F)
1.2
Heating Set Point High Limit (F)
1.3
Unoccupied Cooling Set Point (F)
1.4
Unoccupied Heating Set Point (F)
1.5
Rotating Display
1.6
Fahrenheit Temperature Display
CATEGORY 2.0 OCCUPANCY SCHEDULE
Occupancy Period 1-8
Days Active
2.1-2.8
Start Time
Stop Time
2.9
Schedule Number
2.10
Override Time Limit (Hours)
CATEGORY 3.0 DAMPER
No configuration required.
CATEGORY 4.0 HVAC EQUIPMENT
4.1
Fan Operation For Heat
4.2
Time Guard Between Modes
4.3
Time Guard Override
4.4
LAT (Leaving Air Temperature) Monitoring
4.5
First Stage Cooling Temperature Limit (F)
4.6
Second Stage Cooling Temperature Limit (F)
4.7
First Stage Heating Temperature Limit (F)
4.8
Second Stage Heating Temperature Limit (F)
Auxiliary Relay (0 — No Control, 1 — Occupied Schedule,
4.9
2 — IAQ, 3 — Reversing Valve, 4 — Economizer)
4.10
Optimize Staging
4.11
Cooling Temperature Lockout
4.12
Cooling Lockout Set Point (F)
4.13
Heating Temperature Lockout
4.14
Heating Lockout Set Point (F)
4.15
Minimum Heat Run Time (Minutes)
4.16
Minimum Cool Run Time (Minutes)
4.17
Pre-Occupancy Purge
Fan Switch Control (0 — Use Fan Switch Position,
4.18
1 — Fan Switch ON, 2 — Fan Switch AUTO)
Cool Switch Control (0 — Use Cool Switch Position, 1 — Cool
4.19
Switch AUTO, 2 − Cool Switch OFF)
Heat Switch Control (0 — Use Heat Switch Position, 1 — Heat
4.20
Switch AUTO, 2 — Heat Switch OFF)
CATEGORY 5.0 SENSORS
Room Sensor (1 — Local Room Sensor, 2 — Remote Room
5.1
Sensor, 3 — Average Local Sensor and Remote Room Sensor)
5.2
Zone Temperature Sensor Calibration (F)
5.3
Remote Room Sensor Calibration (F)
5.4
Supply-Air Temperature Sensor
5.5
Supply-Air Temperature Sensor Calibration (F)
5.6
DX Coil Temperature Sensor
5.7
DX Coil Temperature Sensor Calibration
5.8
Outdoor-Air Temperature Sensor (OAT)
5.9
Outdoor-Air Temperature Sensor Calibration
Table 1 — TEMP System Thermostat Categories and Options
DESCRIPTION
Fig. 7 — TEMP System Thermostat
Configuration Buttons
DEFAULT
68
75
80
65
OFF
ON
MTWTF
06:00 AM
06:00 PM
0
1
ON
ON
OFF
ON
45
50
110
105
0
ON
OFF
40
OFF
60
3
3
OFF
0
0
0
1
Zone Temp.
Room Temp.
OFF
Duct Temp.
OFF
Coil Temp.
OFF
Outdoor Temp.
7
MINIMUM
MAXIMUM
50
99
50
99
50
99
40
99
OFF
ON
OFF
ON
NONE
MTWTFSSH
12:00 AM
11:59 PM
12:00 AM
11:59 PM
0
99
0
4
OFF
ON
OFF
ON
OFF
ON
OFF
ON
40
45
45
50
110
180
105
160
0
4
OFF
ON
OFF
ON
10
80
OFF
ON
10
80
1
30
1
30
OFF
ON
0
2
0
2
0
2
1
3
30
180
30
180
OFF
ON
30
180
OFF
ON
30
180
OFF
ON
-40
150
597