3. General description

Grundfos Multilift MD and MLD lifting stations are supplied
complete with collecting tank, pumps, level sensor, LC 221
controller and connection accessories.
The following gives a description of the components.
Fig. 1
Multilift MD front and rear view
Pos.
Description
1
Pump
2
Lifting eye for pumps
3
Nameplate
4
Venting port, DN 70 (outer diameter, 75 mm), open
5
Screw cap for pressure tube and tank inspection opening
6
Vertical inlet, DN 150 (seal is accessory)
7
Fixing point
Non-return butterfly valve, DN 80, with inspection cover
8
and drain screw to lift up the valve flap
Discharge adapter flange, DN 80, to pipe ∅110 with
9
flexible connection piece and 2 clamps
Side or top inlet, DN 50 (seals are accessory).
10
Socket for MD; connecting piece for MLD
Collecting tank with carrying handle moulded into tank
11
body
Port for manually operated diaphragm pump, 1 1/2".
12
Socket with seal for MD; connecting piece with flexible
connection hose and clamps for MLD
13
Horizontal inlet, DN 100 (seal is accessory)
Adjustable inlet disk, DN 100
14
(DN 150 optional as accessory)
15
Separate inspection cover
Fig. 2