Table of Contents About These Instructions ....................... 5 Explanation of Symbols Used .................. 5 Additional Documents .................... 5 Notes on the Product ........................ 6 Product Identification .................... 6 Scope of Delivery...................... 6 Legal Requirements ..................... 6 Manufacturer and Service................... 6 For Your Safety..........................
Page 4
Table of Contents Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
This symbol denotes actions that the user must carry out. RESULTS OF ACTION This symbol denotes relevant results of actions. Additional Documents The following additional documents are available online at www.turck.com: Data sheet Declaration of Conformity IO-Link devices commissioning manual...
For further inquiries in Germany contact the Sales and Service Team on: Sales: +49 208 4952-380 Technology: +49 208 4952-390 Outside Germany, please contact your local Turck representative. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.
132 [5.20] 144 [5.67] Fig. 2: Dimensions TBIL-S4-… 4.1.1 Display Elements The device has the following LED indicators: IO-Link communication I/O status Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Functions and Operating Modes The I/O hubs with IO-Link of the TBIL-S series connect up to 8 digital sensors or 8 digital sensors and actuators with one IO-Link master port. The device provides diagnostics for power supply and short circuit of the sensors and actuators on the IO-Link master.
The FE connection of the device is connected to the reference potential of the installation via the M4 metal screw. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Connecting WARNING Penetration of liquids or foreign objects through leaking connections Danger to life due to malfunction Fasten the M12 connectors with a tightening torque of 0.8 Nm. Always seal unused connectors with respective protection caps. Connecting the supply voltage and IO-Link WARNING Defective power supply unit Danger to life due to dangerous voltages on touchable parts...
Connect the sensors and actuators to the device according to the pin assignment. 1 = V 3 = GND 4 = Signal In/Out C0…C7 Fig. 8: Pin assignment TBIL-S3-8DIP Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 13
Connecting Digital Sensors and Actuators – TBIL-S4-… For connecting digital sensors and actuators, 5-pin M12 connectors are available. Fig. 9: TBIL-S4-…: M12 connector for connecting digital sensors and actuators Connect the sensors to the device according to the pin assignment. = Signal In = GND = Signal In...
0x19 Function Tag read/ Default "***" The application-spe- (25) write cific device function can be stored in this field. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 15
ISDU Object name Access Length Meaning/ Comment Index [Byte] default value Hex. (Dec.) 0x1A Location Tag read/ Default "***" The application-spe- (26) write cific installation loca- tion of the device can be stored in this field. IO-Link object directory – ISDU device parameters: Preferred Index (parameters and diagnostics of the digital in- and outputs) ISDU Object name...
Page 16
C1P2 C1P4 C0P2 C0P4 NOTE This parameter can also be set for all connectors of the module via the IODD. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 17
Activate Output – 0x42 (66), Sub Index 0 this parameeter activates or deactivates the output function of the digital channel. Format Length Byte 1 byte 1 bit per channel Default values are shown in bold. Value Meaning Output function deactivated, channel can only be used as input Output function activated, channel can be used as in- or output...
Page 18
C1P2 C1P4 C0P2 C0P4 NOTE This parameter can also be set for all connectors of the module via the IODD. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 19
Manual Output Reset after Overcurrent – 0x44 (68), Sub Index 0 This parameter defines if a manual reset is necessary after an overcurrent occurred at the digital channel. Format Length Byte 1 byte 1 bit per channel Default values are shown in bold. Value Meaning Automatic recovery mode...
Page 20
C1P2 C1P4 C0P2 C0P4 NOTE This parameter can also be set for all connectors of the module via the IODD. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 21
Undervoltage Diagnosis – 0x46 (70), Sub Index 0 This parameter defines threshold value for the undervoltage diagnostics. Format Length Array of Bytes 2 byte 1 bit per module Default values are shown in bold. Value Meaning Standard lower threshold: 19.2 V (IEC 61131-2) upper threshold: 20.4 V Extended...
Over- Over- Over- Over- current current current current current current current current C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 23
TBIL-S4-8DIP Byte Bit offset Inputs C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Module diagnostics Group Under- Over- dia- voltage voltage gnostics Connector diagnostics – overcurrent sensor supply Over- Over- Over- Over- current current current current TBIL-S4-8DXP Byte Bit offset Inputs C3P2 C3P4...
Page 24
TBIL-S3-…: C0…C3, C4…C7 TBIL-S4-…: C0…C1, C2…C3 Channel diagnostics – overcurrent output Overcurrent CxPy 0 No diagnostic mes- sage Overlaod at the output/short-circuit Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Process Output Data TBIL-S3-8DXP Byte Bit offset Outputs C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 TBIL-S4-8DXP Byte Bit offset Outputs C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Designation Meaning CxPy Output inactive Output active LED Displays The device has the following LED indicators: IO-Link communication I/O status 8.3.1...
TBIL-S4-… Byte 1 Bit offset Over- Over- Over- Over- current current current current Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Overcurrent Output – 0x51 (81), Sub Index 0 Indicates an overcurrent at the corresponding digital output. Format Length Byte 1 byte 1 bit per output 0 = no diagnostics 1 = diagnostic message TBIL-S3-8DXP Byte 0 Bit offset Over- Over- Over- Over- Over-...
Parameter length underrun meter. 0x8035 Function not available Function not available in the device 0x8041 Inconsistent parameter set Inconsistent parameters Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Troubleshooting If the device does not function as expected, first check whether ambient interference is present. If there is no ambient interference present, check the connections of the device for faults. If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type.
Disposal The devices must be disposed of correctly and must not be included in normal household garbage. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
0.010 ms Max. input current 15 mA Potential isolation Inputs to FE, 500 VDC IO-Link Minimum cycle time 2.2 ms Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
13.3 TBIL-S…-8DXP Technical Data Power supply Operating/load voltage 18…30 VDC Operating current < 90 mA Sensor/actuator supply V Supply connectors C0…C7 or C…C3 0.5 A per channel group, short-circuit protec- ted with diagnostics channel groups: TBIL-S3-8DIP: C0…C3, C4…C7 TBIL-S4-8DIP: C0…C1, C2…C3 Total current max.