Bosch Rexroth AG
Maintenance
CAUTION
The battery must not be charged externally, opened, heated over 80 °C and
burnt.
The battery is designed for the use under normal temperature condi-
tions. The max. ambient temperature is 60 °C.
To exchange the battery, proceed as described in the following sections.
Steps for exchanging the battery
1. Shut down the PC.
2. Disconnect the supply voltage of the UPS.
3. Remove fuse F1 on the front side.
4. Open the cover by loosening screw M5 at the UPS, see
of M5 screw for opening the UPS" on page
①
Screw for opening the UPS
Fig. 14-1: Position of M5 screw for opening the UPS
5.
The battery is attached at the cover. Therefore, open the cover carefully
●
40/53
Fire, explosions or burns due to wrong battery
treatment!
40.
VAU 01.1
fig. 14-1 "Position
1
DOK-SUPPL*-VAU*01.1X**-IT02-EN-P