Page 4
This Keysight products are designed for use properly-grounded power receptacle. product must be used in a normal with electrical signals that are rated...
Page 5
Use a dry To return unwanted products, contact cloth or one slightly dampened with The CE mark is a registered trademark your local Keysight office, or for more water to clean the external case parts. of the European Community. information see Do not attempt to clean internally.
M9361A Introduction M9361A Introduction The scope of this Startup Guide is to detail the processes of receiving and installing the Agilent M9361A PXI Downconverter, installing the required software, and verifying basic module operation. If you have any questions after reviewing this information, please contact your local Agilent Technologies Inc. representative or contact us through our website at www.agilent.com/find/M9361A.
(worldwide contact information for repair and service) or refer to the “Support” information on the product web page at www.agilent.com/find/M9361A. 3. Write the following information on a tag and attach it to the malfunctioning equipment: Name and address of owner. A P.O. box is not acceptable as a return address.
Commercial calibration certificate with test data (M9361-UK6) if ordered. Recalibration letter Cable, semi-rigid, A3 (M9361-20001) Cable, semi-rigid, A4 (M9361-20002) All the files contained on the CDs are available for download at www.agilent.com/find/M9361A. Step 3: Install the Software System Requirements ®...
Instrument software, which includes the SFP, device drivers (IVI-C, IVI-COM, and LabVIEW G) and doc- umentation for the M9392A Vector Signal Analyzer. This software is included with your shipment (CD part number M9392-10002), and is also available at www.agilent.com/find/M9392A. Agilent M9361A PXI Downconverter Startup Guide...
1. Install the Agilent IO Libraries Suite from the Agilent IO Libraries Suite CD (E2094-60003) provided in your ship kit. Follow the installer prompts to install the IO libraries. 2. Install the M9361A product software: a. Using the Agilent M9392A PXI Vector Signal Analyzer Software and Product Information CD (M9392-10002), launch the installer.
4. Before inserting the module into the chassis, back the mounting screws out to ensure that there is no inter- ference between the screws and the mounting rails. 5. Holding the module by the injector/ejector handle, slide it into an available PXI (or hybrid) slot, as shown in the figure below. Agilent M9361A PXI Downconverter Startup Guide...
Page 15
11. If you are using a PCIe Cable Interface, such as the Agilent M9021, connect the Cable Interface in the chassis to the PC host per the instructions that came with the Cable Interface. 12. Power up the PXI chassis. 13. Reboot the PC host. Agilent M9361A PXI Downconverter Startup Guide...
When using an M9360A with an M9361A, caution must be exercised. Although the M9360A can accept input power levels of +10 dBm without damage, the operating range of the M9361A is -30 dBm to -160 dBm. Attenuation is required so that the power coming out of the M9360A does not exceed the maximum power that can be applied to the M9361A RF IN connector.
Agilent M9361A PXI Downconverter System Connections This section contains a cabling diagram for the Agilent M9392A PXI Vector Signal Analyzer, a cable and module association table, and a block diagram for the M9361A. Agilent M9392A PXI Vector Signal Analyzer Cabling Diagram...
Step 5: Verify Operation of the M9361A Module Agilent M9361A Block Diagram Step 5: Verify Operation of the M9361A Module The intention of this step is to verify correct operation of the newly installed module. Run Agilent Connection Expert (from the desktop icon, or from Start > Programs > Agilent IO Libraries Suite > Agilent Connection Expert).
Conduct M9361A Operational Check (optional) Requirements for Operational Check The Agilent M9361A PXI Downconverter operational check measures the signal paths from the LO IN and RF IN connectors to the IF OUT connector. The following process demonstrates that all associated switches, connectors, cables and circuitry are operational.
Page 20
Step 5: Verify Operation of the M9361A Module Hardware Description Agilent E8257D-532 or E8267D-532 Precision Signal Generator 31.8 GHz Agilent N1913A or N1914A Single / Dual Channel Power Meter Agilent N8485A, Option 100 10 MHz to 26.5 GHz Power Sensor...
Page 21
1. Verify that all relevant hardware is turned on. 2. Verify that the M9302A and M9361A paths are correctly set from the SFPs and that the signal generator is set to the proper power/frequency and that all cables are properly connected. All SMA connector are torqued to 8 Lb-In (0.904 Nm).
> Agilent > M9392 > AgM9361 LabVIEW Help. M9361A Specifications The Data Sheet for the M9361A is included on the Agilent M9392A VSA Software and Product Information CD that came with your module. This document contains specification information. To find the latest update, go to http://cp.literature.agilent.com/litweb/pdf/5990-6059EN.pdf.
Need help?
Do you have a question about the M9361A and is the answer not in the manual?
Questions and answers