2.6.2

Installing the BIS M-41_ RS485

BCC07WR
BCC0ET0
BIS M-411
Gateway
to Host
The BIS M-41_-067-001-04-S92 Compact processor is designed for Subnet16™ RFID
applications, where the compact processor is connected in an RS485 network via
Subnet16™-compatible cables to the host through a Gateway or Hub.
1. To mount the BIS M-41_ Compact processor:
a) For the BIS M-410 Compact processor, attach to the polycarbonate mounting bracket
(for metallic isolation) using the two sets of M4 screws, washers and nuts provided as
shown in
Figure
Tighten all screws to 0.7 Nm (6 lbs per inch).
b) For the BIS M-411 Compact processor, fasten it to the mounting surface using two
M5 (#10) screws, washers and nuts (not provided). Tighten all screws to between 1.3
and 1.7 Nm (12-15 lbs per inch).
2. Attach a Subnet16™ compatible cable (i.e. BCC0ET0) to the M12 5-pin male Subnet16™
connector on the compact processor. Connect the other end of this cable to your
Subnet16™ network.
3. To complete the Subnet16™ network installation, including power supply wiring, trunk
wiring, network termination, Gateway/Hub wiring, and for a complete list of compatible
accessory cables and Subnet16™ network layout examples, see the Subnet16™
Gateway or Subnet16™ Hub Manuals.
After installation, the Subnet16™ network can be configured through the Subnet16™
Gateway/Hub using the Balluff Dashboard™ Configuration Tool. See the Dashboard™
Configuration Tool Manual for details.
19
BCC07WR
BCC0ET0
to
Configuration PC
Figure 17 - RS485 Typical Layouts
2. Fasten the other end of the mounting bracket to your work area.
BCC07WR
BIS M-411
VDC GND
INSTALLATION
BCC0ET0
BCC07WR
BIS M-410
to Power Supply