Advertisement

Quick Links

20000005401
Tube Mill_012017
Tube Mill control
®
IKA
Tube Mill 100 control
®
IKA

Advertisement

Table of Contents
loading

Summary of Contents for Imlab IKA Series

  • Page 1 20000005401 Tube Mill_012017 Tube Mill control ® Tube Mill 100 control ®...
  • Page 2: Table Of Contents

    Source language: German Contents Page Declaration of conformity Explication of warning symbols Safety instructions Correct use Unpacking Useful information Interfaces and outputs Commissioning Switching on the instrument Factory setting Setting menu parameters Setting working parameters Warning messages Error codes Using the coupling extractor Maintenance and cleaning Accessories Technical data...
  • Page 3: Safety Instructions

    Safety Instructions • The milling tube must only be attached and removed • Read the operating instructions completely before while the motor is stationary. starting up and follow the safety instructions. • Keep the operating instructions in a place where they Always open the milling tube care- can be accessed by everyone.
  • Page 4: Unpacking

    The Tube Mill control is not suit- The safety of the user cannot be guaranteed: WARNING able for grinding wet materials - If the instrument is operated with accessories that are not with too much water. Otherwise, supplied or recommended by the manufacturer the water may leak from the grinding tube and damage - If the instrument is operated improperly contrary to the the drive unit.
  • Page 5: Interfaces And Outputs

    Please note that the mill feed heats up again extremely Dry ice cooling (CO First put the feed product into the milling tube and then quickly during crushing (it may reach room temperature add about half a teaspoon of dry ice snow. Thoroughly again after approximate 30 seconds of grinding).
  • Page 6: Commissioning

    OUT_SP_X m Set target speed value, input: rpm START_X Switch on appliance remote function. Start value function with setting. IN_SOFTWARE Request software ID, number, date and version Commissioning Pay attention to the ambient conditions listed in the “Technical Data”. Check whether the voltage given on the type plate cor- responds to the available mains voltage.
  • Page 7: Factory Setting

    After the system check screen, the working screen appears Note: Above figures show specified values corresponding to the default settings at delivery. and the instrument is ready for operation. Factory setting The device is supplied with following factory setting: Resetting parameters to factory setting: To reset the parameters to the factory settings, proceed Menu Settings: as following:...
  • Page 8: Setting Working Parameters

    • Basic guide to using the menu system: The “timer max” setting will be stored automatically when operation is over or the device is switched off. Selecting a menu Press the “Menu/Back” key (G) in working screen to Note: During setting the “timer max“ by rotating the enter menu system.
  • Page 9: Warning Messages

    Setting “Timer” value (timer sec) in working screen: Setting “Int” timer (int sec) in working screen: Press “Timer” key (E) to activate the timer setting in Press “Int” key (F) to activate the interval setting in the the working screen. working screen.
  • Page 10: Using The Coupling Extractor

    Using the coupling extractor Milling tube coupling broken: The milling tube coupling may be broken when the grinding material is too much or too hard. Pull the broken coupling out from the drive unit: Fit the coupling extractor in clockwise direction. The coupling puller is properly attached to the coupling af- CLICK CLICK...
  • Page 11: Accessories

    Accessories Tube mill control: Tube mill 100 control: • MT 40 Milling tube • MT 100 Milling tube • MMT 40 Multi-use milling tube • MT 40 Milling tube • Labworldsoft ® • MMT 40 Multi-use milling tube ® • Labworldsoft See more accessories on www.ika.com.

This manual is also suitable for:

Ika tube mill controlIka tube mill 100 control

Table of Contents