4.7 Electrical connections

Qualified personnel should carry out connecting unit to the main power.
Be sure to check the local codes in your area.
Before connecting the unit to the electrical supply, verify the data nameplate for the proper electrical information.
Voltage tolerance is +/- 10%.
Dryer are supplied with power cord and plug (two poles and ground).
Be sure to provide the proper fuses or breakers based on the data information located on the nameplate.
A residual-current device (RCD) with In =0.03A is suggested. The cross section of the power supply cables
must comply with the consumption of the dryer, while keeping into account also the ambient temperature, the
conditions of the mains installation, the length of the cables, and the requirements enforced by the local power
provider.
Important: ensure that the dryer is earthed.
Do not use any socket adapters at the mains plug.
If the mains plug needs to be replaced, this must only be done by a qualified electrician.
4.8

Condensate drain

The condensate is discharge at the system pressure.
Drain line should be secured.
Never point the condensate drain line towards anybody.
The dryer comes already fitted with a timed condensate drainer (solenoid valve controlled by electronic
instrument) or with an electronic condensate drainer (optional).
Connect and properly fasten the condensate drain to a collecting plant or container.
The drain cannot be connected to pressurized systems.
Don't dispose the condensate in the environment.
The condensate collected in the dryer contains oil particles released in the air by the
compressor.
Dispose the condensate in compliance with the local rules.
We recommend to install a water-oil separator where to convey all the condensate drain
coming from compressors, dryers, tanks, filters, etc.