A fault, what to do?
Attention!
Repairs must only be carried out by an authorised technician. Improper repairs can lead to risk of serious
injury to the user.
If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you
can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary
visit by customer service personnel.
Faults that the customer can troubleshoot himself
Fault
Water flow-rate is too low
A high water temperature is
set, but it is not reached.
The water is not warm.
LED status display flashes
red.
If the fault could not be eliminated, please call customer service.
Faults that the customer service specialist should troubleshoot
Fault
Water flow-rate is too low
despite cleaning of filter
using the water tap or
showerhead
Faults that are automatically remedied
Fault
From time to time, cold
water flows out.

Environmentally-friendly disposal

Dispose of the packaging in an environmentally sound
manner.
This appliance is labelled in accordance with
European Directive 2012/19/EU concerning
used electrical and electronic appliances
(waste electrical and electronic equipment –
WEEE).
The guideline determines the framework for
the return and recycling of used appliances as
appli cable throughout the EU.
Please ask your specialist retailer about current
disposal facilities.
6 720 820 328 - 9001217888 | (06.19)
Cause
The filter in either the water tap or the
showerhead is clogged.
The continuous-flow heater is connected
to a thermostatically-controlled water tap.
The fuse in the fusebox has tripped/blown. Check the fuse in the fusebox.
The supply temperature has dropped or
the appliance has reached the power limit.
Fault in the appliance
Cause
A filter in the appliance is clogged.
Cause
The air sensor in the appliance detects
air in the water and momentarily switches
the heating element off.
Solution
Remove the filter and either clean it or
descale it.
Set the temperature on the continuous-
flow heater to "60 °C".
Set the temperature lower e. g. "30 °C".
Please contact customer service.
Solution
Get a servicing expert to clean the
appliance.
Solution
After a few seconds, the continuous-
flow heater automatically goes back into
operation.
Guarantee
The guarantee conditions for this appliance are as
defined by our representative in the country in which it
is sold.
Details regarding these conditions can be obtained from
the dealer from whom the appliance was purchased.
The bill of sale or receipt must be produced when mak-
ing any claim under the terms of this guarantee.
Subject to change without notice.
Robert Bosch Hausgeräte GmbH

Advertisement

Table of Contents
loading

Table of Contents