USER GUIDE:
COMFORT VALUE
1. A
PPLICATION
The
Shower chair is designed to be used as a self-propelling or attendant operated.
COMFORT VALUE
All the parts being interchangeable to facilitate simple change of operation should this be required.
NOTE: The standard CVSC/ATT and the standard CVSC/SP chair is only supplied in one configuration, with the option of
additional parts being purchased separately. Please refer to the Technical Manual for information concerning
optional extras
2. S
AFETY
 Please read this User Manual carefully before using the CVSC/ATT or CVSC/SP chair. Any person
who is likely to use the equipment needs to familiarise themselves with the user instructions.
 Before each use the chair should be visually inspected to ensure it is free from defects.
 We advise that vulnerable service users are not left unattended to use this equipment.
 Further guidance is available via
3.
(
)
CHAIR INSPECTION
SWL
All our standard chairs are designed and tested to meet the requirements of the stated Safe Working
Load. For the CVSC/ATT the Safe Working Load (SWL) is 180Kgs. For the CVSC/SP the Safe Working
Load (SWL) is 150Kgs.
Before each use the chair and associated accessories must be visually inspected for the following:
 Condition of frame – not bent or twisted, coating not perished (where applicable)
 Castors are correctly adjusted and locking pins fitted
 Castors/wheels are not loose
 Brakes operate
 Seat is secure
 Seat not split
 Footrests (if fitted) lock in place and the foot plates are correctly adjusted and secure
 Backrest not split
 Armrests are secure
 Arm pads are secure and not split
 Lap-strap (if fitted) not entangled in wheels and buckle not broken
 Commode pan (if fitted) not cracked and fits securely
NOTE: This is not an exhaustive list and additional consideration should be made for the
severity of use, the environment where equipment is used.
4.
INSTRUCTIONS FOR USING YOUR CHAIR
4.1.1 Adjusting the Seat Height
i. Remove the pin clip from the leg.
ii. Select the desired seat height by sliding out the leg from the frame (This is a telescopic
action).
iii. Refit pin clip.
iv. Repeat the adjustment for the other legs.
v. Ensure all legs are adjusted equally.
*NOTE: Height adjustment can only be achieved when the chair is not in use.
4.1.2 Self Propelling Model Adjusting the Wheels (Metal Plate)
To change / adjust the size, height or position of the self-propelling wheels, a 19mm spanner,
socket and ratchet are required (not supplied).
i. Remove the covers from the axle bolts and wheel centre.
ii. Remove the locking nut & washer from the axle bolt.
Shower Chair
(CVSC/ATT + CVSC/SP)
www.careandindependence.com
*
(Attendant Model only)
UG/CVSC-01