Summary of Contents for Swagelok Air-Actuated Hydraulic Swaging Unit
Page 1
Air-Actuated Hydraulic Swaging Unit (AHSU) Setup and Operating Instructions AHSU with base Definitions Statements and symbols are used in this document to identify safety concerns. Read the definitions below before setting up and operating the AHSU. Caution: Statements that identify conditions or Warning: Statements that identify conditions or practices that could result in damage...
Page 2
50 (3.5) 35 (2.4) Return the AHSU to your independent 10M0 60 (4.2) 40 (2.8) Swagelok sales and service representative 12M0 70 (4.9) 45 (3.1) if any signs of hydraulic fluid leakage or malfunction occur. 3. Select the proper size die head (reference the size marked on each die head).
Page 3
Operation Gauging Instructions 1. Install Swagelok nut and ferrules onto the die Use of the Swagelok AHSU gap inspection gauge head in order and orientation shown. assures the installer or inspector that the fitting has Note: The front edge of the nut should line up been sufficiently tightened.