Download Print this page

Advertisement

Quick Links

Connections and operating modes of Z1 and ZH1
This manual applies to all standard and all-in-one
Details concerning decoder with 16 terminals are marked with colored
background.
= DQG =+ DUH VKLSSHG FRQÀJXUHG IRU FRQWURO RI WZRDVSHFW OLJKW VLJQDOV
(red/green) at DCC accessory addresses 1 to 4 (8 for Zx-16)
Z1 and ZH1 provide 8 or 16 equal and independently controllable function
outputs. They can be switched on and off with commands from the digital
control unit or with locally connected key buttons.
The decoder uses DC power to switch the connected accessories, regardless
of whether the decoder's terminals Trafo are connected to a transformer, a
power supply or the track signal.
The following pictures show the function principle of Z1 and Z1H. On the left
side the power supply and the track terminals and on the other side the
function outputs and the local supply terminals for accessories are depicted.
The Z1 operates a switch between function output and local ground whereas
the ZH1 switches the function output to the local supply. Accessory devices
of the Z1 are connected between function output and local supply, devices
for ZH1 are attached to function output and ground.
#
=
decoder
decoder
of series Z1 and ZH1
Z1
#
=
decoder
ZH1
Z1
Qdecoder

Advertisement

loading

Summary of Contents for Qdecoder Z1 Series

  • Page 1 Connections and operating modes of Z1 and ZH1 This manual applies to all standard and all-in-one Qdecoder of series Z1 and ZH1 Details concerning decoder with 16 terminals are marked with colored background. = DQG =+ DUH VKLSSHG FRQÀJXUHG IRU FRQWURO RI WZRDVSHFW OLJKW VLJQDOV...
  • Page 2 The lamps of a light signal are connected to the function outputs A0 to A7 (A15) of the decoder. The blue terminals are used as common return conductor for the Z1 series. For ZH1 decoder the common return is applied to the brown ground terminals. For a group of 4 function outputs a blue and a brown terminal is provided.
  • Page 3 Î Motoric turnout drives Motoric turnout drives can not be controlled by a decoder of the Z1 or ZH1 series. Apply a Z2 series decoder instead. Î Additional key buttons for switching turnouts etc. Turnouts or semaphore signals can be switched Key button for drive Turnout...
  • Page 4 The table lists the commands for addresses 1 to 4. If a command with address 5 to  LV UHFHLYHG WKH IXQFWLRQ RXWSXWV DUH FRQÀJXUHG IRU DGGUHVVHV EHJLQQLQJ ZLWK  DQG Qdecoder Setup IROORZLQJ )RU GHWDLOV RI DGGUHVV FRQÀJXUDWLRQ VHH IROGHU Å...
  • Page 5 Î Command 3 : Two-Aspect Block Signals (red/green) The lamps of a block signal are connected to terminals of an output pair A0/A1 to A14/A15. The common return conductor of the signal is attached to the blue terminal of a Z1 or the brown terminal of a ZH1.
  • Page 6 Command to switch 6LJQDO 6LJQDO 6LJQDO 6LJQDO 6LJQDO 10 11 10 11 11 12 13 13 14 L6 is switched on by command „11 “ and off with command „11 “. For a decoder with 8 function outputs the third signals has only two aspects. The correspondence between adresses and signals can be changed by programming the following CVs: =XEHK|UDGUHVVHQ...
  • Page 7 2SHUDWLQJ 0RGHV XVLQJ &RQÀJXUDWLRQ 9DULDEOHV 7KH SURSHUWLHV RI D ==+ GHFRGHU FDQ EH FKDQJHG ZLWK YDULRXV FRQÀJ- Qdecoder uration variables (CVs). For details see folder “Overview on Qdecoder CVs” or the „ Book“. &RQÀJXUDWLRQ YDULDEOHV FDQ EH UHDG DQG ZULWWHQ ZLWK PRVW GLJLWDO FRQWURO XQLWV )RU details please refer to the user guide of your control unit.
  • Page 8 “0”, and so on. Î Examples This chapter presents some examples of useful applications for the Z1/ZH1 Qdecoder series. They give an impression of the enormous diversity of applications and should provide inspiration for your own ideas.
  • Page 9 Example how to “read” the following table: A turnout is connected to two function outputs („1“ and „2“, which could be any pair of consecutive outputs). The Mode-CV RI WKH ÀUVW IXQFWLRQ RXWSXW KDV WR EH VHW WR ´µ 7KH UHTXLUHG ´µ IRU WKH 0RGH&9 RI output „2“...
  • Page 10 $SSOLFDWLRQ Mode Address IXUWKHU &9 SURSHUWLHV Staircase lighting &RQÀJXUH W and t Puls Light (3 times on/off) Is switched on and off 3 times Irregular light = 90, t = 70, t = 80, t = 100 Light &RQÀJXUH W and t Addresses A Blink...

This manual is also suitable for:

Zh1 series