4 Installation

4.1 Mechanical installation

4.1.1 Installation area

DANGER: Potentially explosive atmosphere hazard
The operation of the booster set in environments with potentially explosive atmospheres or with
combustible dusts (e.g.: wood dust, flour, sugars and grains) is strictly forbidden.
WARNING:
 Always wear personal protective equipment
 Always use suitable working tools
 When selecting the place of installation and connecting the unit to the hydraulic and electric
 Ensure that the ingress protection rating of the unit (IP 55, type 1) is suitable for the installation
CAUTION:
 Input protection: to ensure the IP55 (type 1) protection index make sure that the unit is closed
 Before opening the terminal box cover, make sure that there is no water in the unit
 Make sure that all unused cable glands and cable holes are correctly sealed
 Make sure that the plastic cover is correctly closed
 Do not leave the terminal box without cover: risk of damage due to contamination
 Make sure that the electric panel is correctly closed.
Outdoor installation of the booster set
In case of outdoor installation of the booster set, ensure appropriate cover (see example in
Figure 6). The size of the cover must be such as to ensure protection of the booster set against
snow, rain and direct sunlight.
Figure 6: Outdoor installation of the booster set
power supplies, strictly comply with current regulations.
environment.
correctly.
en – Original instructions
15