RST Instruments Push-In Pressure Cell Installation Manual

With piezometer

Advertisement

Quick Links

Push-In Pressure Cell
with Piezometer
Installation Manual
All efforts have been made to ensure the accuracy and
completeness of the information contained in this document. RST
Instruments Ltd reserves the right to change the information at any
time and assumes no liability for its accuracy.
Copyright © 2019. RST Instruments Ltd. All rights reserved.
Document Number: LPM0032A
Release Date:
September 17, 2019
RST INSTRUMENTS LTD.
11545 Kingston St.,
Maple Ridge, BC
CANADA V2X 0Z5
SALES + SERVICE + MANUFACTURING:
604 540 1100
|
info@rstinstruments.com
TOLL FREE (USA & Canada)
|
1-800-665-5599
www.rstinstruments.com
LPM0032A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Push-In Pressure Cell and is the answer not in the manual?

Questions and answers

Summary of Contents for RST Instruments Push-In Pressure Cell

  • Page 1 RST Instruments Ltd reserves the right to change the information at any time and assumes no liability for its accuracy. Copyright © 2019. RST Instruments Ltd. All rights reserved. Document Number: LPM0032A Release Date: September 17, 2019 RST INSTRUMENTS LTD.
  • Page 2 Push-In Pressure Cell with Piezometer Installation Manual EVISION ISTORY Rev. Revision History Date Prepared By Approved By Initial release. 2019-Sep-17 LPM0032A Page ii...
  • Page 3: Table Of Contents

    ....................3 ERVICE AND EPAIR IST OF IGURES Figure 1-1 Push-In Pressure Cell with components ..............1 Figure 3-1 Filter set screw and filter ................... 2 Figure 4-1 Typical Installation of a Push-In Pressure Cell ............3 LPM0032A Page iii...
  • Page 4: Introduction

    RESSURE ELL WITH COMPONENTS The Push-In Pressure Cell is designed to be pushed into the ground where it can measure total earth pressure and pore water pressure within soil. Typically, Push-In Pressure Cells are installed in fine-grained cohesive soils, including very soft to stiff clays.
  • Page 5: Installation

    GLYCOL SET SCREW WILL DAMAGE THE RESSURE Submerge the Push-In Pressure Cell in a bucket of flat water (i.e. water that has been sitting for 24 hours). This will fill the space above the diaphragm with water. Let the pressure cell sit in the water to completely saturate the filter.
  • Page 6: Ervice And Epair

    Push-In Pressure Cell with Piezometer Installation Manual Push the Pressure Cell about 1 meter past the bottom of the pilot hole using standard drill rods or Cone Penetration Test (CPT) rods. The rods may either be left in place or retrieved at a later stage after the measurements are completed.