Air inlets / outlets ..............4 Condensation traps ............... 4 Selecting a location ............5 Determined on the basis of EN 14511 or Truma test conditions Cut-out installation 400 x 400 .......... 5 Installation with new cut-out ........... 5 Power supply Preparation for power cable connection and control 230 V –...
Only competent and trained staff (experts) are permitted Recommended for optimum sealing when retrofitting in to install and repair the Truma product and to carry out the vehicles with 400 x 400 mm cut-out. function test, at the same time observing the installation and operating instructions and the currently recognised technical regulations.
The clearance around the external unit must be 20 mm at the front and 50 mm at the side. At least 20 mm of clearance must be left at the rear. Truma recommends clearance of The condensation is led away via the roof of the vehicle.
Selecting a location Cut-out installation 400 x 400 Once the roof-mounted air conditioning system has For optimum sealing we recommend the use of the sealing been installed, any nearby exhaust cowl must extend frame that is available as accessory (part no. 40091-19000). at least 10 cm above the air conditioning system.
Preparation for power cable connection and Route the power cable and control panel cable to the connec- tion point (lengthen the mains cable with the provided Wago control panel cable clamps if necessary). Provide the lead-through to the connection point for the If the lighting of the air distributor is also going to be mains cable and control panel cable, e.g.
If the screws are used more than once (e.g. after removal) The covering tape that is available as an accessory can they must be coated with low-strength screw sealant be used to compensate for the gap between the air dis- again (e.g.
Function check / remote control mounting Attach the mounting for the remote control in the required location. All appliance functions must subsequently be tested as described in the operating instructions. The installer must check that the condensation traps are clear after installing the system.
Page 12
In Australia, always notify the Service Australia if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). Having the equipment model and the serial number ready (see type plate) will speed up processing. Leisure-Tec Australia Pty. Ltd.