    To avoid transportation damage, the device may only be sent to the Truma Service Centre if agreed beforehand. The power supply must be disconnected from the mains (all poles) before opening the housing.
  • Page 3: Notes On Using Air Conditioning Systems

    – changes to the device (including accessories), Park the vehicle in the shade if possible. – failure to use original Truma parts as replace- ment parts and accessories, Darkening with blinds reduces the amount of – failure to follow the installation and operat- heat insolation.
  • Page 4: Operating Instructions

    Operating instructions Remote control The symbols in the display are visible depending on the settings. Setup Resend / data transmission Sleep function Cooling Fan level Automatic Temperature mode Circulated Time Timer On/O time Mode Mode selection button – Cooling – Automatic –...
  • Page 5: Start-Up

    Start-up Sleep function Before switching on, be sure to check that the camp site has In “Sleep function” the internal and external fans operate at adequate power supply fusing (230 V). slow speed and are therefore extremely quiet. In order to prevent the power cable of the recreational Switching off vehicle from overheating (minimum cross-section 3 x 2.5 mm²) the cable drum must be fully unwound.
  • Page 6: Ir Receiver And Manual On / Off

    IR receiver and manual on / off IR remote control battery change There is an additional pushbutton on the IR receiver (m), with Only use micro-batteries that will not leak, type LR 3, AM4, which the unit can also be switched on and off without the AAA, MN 2400 (1.5 V).
  • Page 7: Accessories

    Accessories Troubleshooting Aventa air filter kit, 2 pcs Fault Cause / Remedy for air distributor, not for air distributor small (Part. No. 40091-16800) Appliance not cooling – Thawing procedure in progress – Remote control temperature setting reached or too high Appliance providing in- –...
  • Page 8: Technical Data

    Technical data Installation dimensions (in mm) Determined on the basis of EN 14511 or Truma test conditions Power supply 230 V – 240 V , 50 Hz Power consumption Cooling: 4.4 A Starting current 28 A (150 ms) Cooling power 2.2 kW (T35 / T35)
  • Page 9: Air Inlets / Outlets

    – The company will only provide service on presentation of proof of purchase, on either the Truma product, or the Cara- van / RV / Pleasure Craft in which the Truma product has been installed, to any authorised service agent. The purcha- ser must allow the service agent to photocopy the proof of purchase to facilitate his claim to the manufacturer.
  • Page 12 In Australia, always notify the Service Australia if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). Having the equipment model and the serial number ready (see type plate) will speed up processing. Leisure-Tec Australia Pty. Ltd.