Download Print this page

Specifications - Eastwood 31223 Instructions Manual

Non-contact infrared thermometer

Advertisement

SPECIFICATIONS

Temperature range
Accuracy
Repeatability
Response time
Spectral response
Emissivity
Ambient operating range
Relative humidity
Storage temperature
Ambient temp range to guarantee accuracy 23˚C to ~28˚C (73˚F to 82˚F)
Weight/dimensions
Power
Distance to spot ratio
NOTE:
- Display "AL" indicates ambient temperature is lower than 0˚C (32˚F)
- Display "AH" indicates ambient temperature is higher than 60˚C (140˚F)
- "AL" or "AH" displayed in normal ambient temps may indicate failure
6
Eastwood Technical Assistance: 800.544.5118 >> techelp@eastwood.com
-30˚C to 550˚C (-22˚F to 1022˚F)
±4% or ±4˚C of reading, -30˚C to 0˚C (-22˚F to 32˚F)
±2% or ±2˚C of reading, 0˚C to 100˚C (32˚F to 212˚F)
±4% or ±4˚C of reading, ≥100˚C (212˚F)
1% of reading or 1˚C
500msec, 95% response
8-14um
0.1-1.0, adjustable
0˚C to ~60˚C (32˚F to 140˚F)
10-95% RH noncondensing
-20˚C to ~60˚C (-4˚F to 140˚F)
155g (5.5oz) / 165x72x41mm (6.5"x2.8"x1.6")
9V battery, 6F22 or NEDA 1604
8:1