Non-contact infrared thermometer

Advertisement

THERMOMETER FUNCTION KEY
1. TRIGGER – Pull to turn thermometer on. The instantaneous temperature at the measurement
point is displayed on "E" on the LCD display (FIG. C).
2. LASER POINTER BUTTON – Press to toggle between "on" and "off."
3. BACKLIGHT/UP BUTTON – Press to switch backlighting on and off as needed during use.
In "Alarm Temperature" and "Setting Emissivity" modes, press to increase setting value.
4. MODE BUTTON – Press to change between measurement modes:
MAX – Displays the maximum temperature measured during the duration while the trigger
was depressed. Resets when trigger is pulled again.
MIN – Displays the minimum temperature measured during the duration while the trigger
was depressed. Resets when trigger is pulled again.
AVG – Calculates the average of all temperatures measured during the time while the
trigger was depressed. Resets when trigger is pulled again.
HAL – High temperature alert. Using the UP or DN button, set the desired high alert
temperature. When the temperature exceeds the set temperature, the LCD readout
will display "H".
LAL – Low temperature alert. Using the UP or DN button, set the desired low alert
temperature. When the temperature drops below the set temperature, the LCD readout
will display "L".
5. T/DN BUTTON – Press to change between ˚C and ˚F on display. In "Alarm Temperature" and
"Setting Emissivity" modes, press to decrease setting value.
6. SET BUTTON – Press to set emissivity. Use UP or DN buttons to adjust between 0.1 and 1.0,
then press SET again to exit setting mode.
7. LCD READOUT – See display key above
8. BATTERY DOOR – Use fi nger indents
to pry door open.
FIG. B