Application; Installation - STA-RITE SR-4000 Owner's Manual

Chemical feed system
Table of Contents

Advertisement

APPLICATION

Adding pool chemicals automatically on a regular basis will
minimize the high and low swings associated with intermit-
tent manual chemical maintenance. By adding chemicals
automatically on a regular cycle, a more consistent level can
be achieved than is possible with weekly or semi-weekly
manual additions. The pump can lift 15 feet from the supply
tank, and push up to 20 feet vertically and 65-70 feet hori-
zontally to the final injection point. Injecting into pressurized
lines up to 30 PSI is possible without special considerations.
The SR-4000 and SR-6000 can also be set on a continuous
setting and cycled by an automatic controller.
Risk of chemical burns and explosion.
Always consult the chemical manufacturer for
proper storage, use, handling and compatability for use
with a peristaltic pump.
Follow all warnings and instructions provided by the
chemical manufacturer.
Never dispense different chemicals through the
same supply tubing.
Always flush the pump and the supply tubing thor-
oughly with water prior to changing to another chemical.
Always inject chemicals into the return line down-
stream from all pool equipment.
Always wear protective clothing and face shield ap-
propriate to the chemical(s) you are handling.
SR-4000/
SR-6000
To Open Body
of Water
Chemical
Supply
Figure 2: Plumbing Setup.
Water System
Return Line
To Pressure
Injection
OR
Body of Water
3969 0501

INSTALLATION

Mounting
Mount the SR-4000/SR-6000 Dispenser on a wall near the
chemical supply. The dispenser should be less than 15 feet
from the chemical container and less than 70 feet from the
injection point. Although further distances are possible,
performance may be reduced. Testing is recommended for
greater distances. Use appropriate hardware for the chosen
mounting surface. Mounting location should be protected
from exposure to direct spray and direct sunlight whenever
possible.
Plumbing
Connect the chemical tubing and drum kit following the
instructions included with the plumbing kit. Additional
tubing and hardware may be required depending on dis-
tances and configuration. Secure the injection point as re-
quired for either a pressure line or an open body of water.
Blue
Yellow
24 VAC
Output to
PCA Board
Blue
Yellow
24 VAC
Output to
PCA Board
Blue
Yellow
24 VAC
Output to
PCA Board
Figure 3: 24VAC Transformer Connections.
3
Orange
Red
Black
115 VAC Input
White
from Power Cord
(Standard)
Orange
Red
Black
208 VAC Input
from Conduit
White
Orange
Red
Black
230 VAC Input
from Conduit
White