Furnace Removal - Suburban DD-17DSI Service Manual

Rv furnaces
Hide thumbs Also See for DD-17DSI:
Table of Contents

Advertisement

To replace parts or service the SUBURBAN family of RV furnaces, it is necessary to follow these steps:
DD-17DSI
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Remove the vent cap assembly by removing applicable screws.
3.
Remove the cabinet front two (2) screws.
4.
Remove the applicable screws securing the furnace to the coach floor.
5.
Remove duct from side of furnace, if equipped.
6.
Remove the furnace from the cabinet area to gain access to combustion chamber and applicable parts.
7.
Some parts can be accessed without removal of the complete furnace.
8.
To re-install, reverse this procedure.
9.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
NT-12/16/20S
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Remove the vent cap assembly by removing applicable screws.
3.
Remove the cabinet front two (2) screws.
4.
Remove the (1) one tie down screw securing the chamber to the cabinet.
5.
Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.
6.
To re-install, reverse this procedure.
7.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
NT-12/16/20SE
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Remove the vent cap assembly by removing applicable screws.
3.
Remove the cabinet front two (2) screws.
4.
Remove the (2) two tie down screws securing the chamber to the cabinet.
5.
Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.
6.
To re-install, reverse this procedure.
7.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
NT-24/30/34SP and NT-40
1.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
2.
Remove the vent cap assembly by removing applicable screws and one (1) flue retaining screw. Not applicable to NT-40.
3.
Remove the cabinet front two (2) screws.
4.
Remove the (2) two tie down screws securing the chamber to the cabinet.
5.
Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.
6.
To re-install, reverse this procedure.
7.
Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.
SF-20/25/30/35/42, SFV-20/25/30/35/42, SH-35/42 and SHD-2542
1.
Remove the vent cap assembly from the outside access door by removing applicable screws, also the four (4)
the door to the frame. Remove the door to gain access to the furnace.
2.
Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.
3.
Remove the (1) one tie down screw securing the chamber to the cabinet.
4.
Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and
5.
To re-install, reverse this procedure.

FURNACE REMOVAL

FURNACE REMOVAL
42
screws retaining
applicable parts.

Advertisement

Table of Contents
loading

Table of Contents