IDRONIK TS 13
Instantaneous gas
water heater, type C.
ISTRUCTIONS FOR
INSTALLER, USER
AND SERVICE MAN
88

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDRONIK TS 13 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Unical IDRONIK TS 13

  • Page 1 IDRONIK TS 13 Instantaneous gas water heater, type C. ISTRUCTIONS FOR INSTALLER, USER AND SERVICE MAN 00333639 - 2 edition - 04/2011...
  • Page 2: Table Of Contents

    Failure to follow the instructions indicated in this manual, which is supplied with the appliance, could cause injury to persons, animals or damage to property. UNICAL shall not be held liable for any injury and/or damage. CONTENTS GENERAL INFORMATIONS .....................................
  • Page 3: General Informations

    Any other use of this appliance will be considered improper.UNICAL declines any responsibility for any damages or injuries caused by an improper use; in this case the risk is completely at the user’s responsibility.In order to use the appliance according to the scopes it was designed for it is essential to carefully follow the instructions indicated in this guide.
  • Page 4: Safety Warnings

    Servicing or repairs of the appliance must be carried out by UNICAL authorised service technicians; UNICAL recommends drawing up a service contract. Bad or irregular servicing could compromise the safe operation of the appliance, and could cause injury to persons, animals or damage to property for which UNICAL shall not be held liable.
  • Page 5: Data Badge

    General information 1.6 - DATA BADGE CE marking The CE marking certifies that the appliance complies with: The essential safety requirements of the relevant gas appliances directive 2009/142/EC. The label is positioned on the external part of the frontal shell (to the left side). KEY: 1 = CE surveillance Notified ®...
  • Page 6: General Warnings

    Please read carefully the instructions contained in this manual as they provide important indications regarding the safe Any repairs must be carried out by Unical authorized installation, use and servicing of this appliance. technicians and using only original spare parts. Non- observance of the above requirement may jeopardize the Keep this manual in a safe place for future reference.
  • Page 7: Technical Features And Dimensions

    Technical features and dimensions TECHNICAL FEATURES AND DIMENSIONS 2.1 - TECHNICAL FEATURES The water heater IDRONIK TS 13 is an appliance operating COMPONENTS DESCRIPTION: on gas, with a two section burner which distinguishes for its • Two section burner extremely reduced depth: only 10 cm.
  • Page 8: Main Components

    10 D.C.W. inlet 1/2’’ 11 Water heater drain cock 12 IGas inlet 1/2’’ 13 Electrical supply cable 2.4 - OPERATIONAL DATA 2.5 - GENERAL FEATURES IDRONIK TS 13 Nominal Input Qn D.H.W. drawing range l/min. da 2,8 a 12,2 22,5 D.H.W.
  • Page 9: Instructions For The Installer

    Instruction for the installer INSTALLATION ISTRUCTIONS 3.1 - GENERAL WARNINGS WARNING! The appliance must be installed only on a WARNING! vertical flat wall, made of non combustible This appliance has to be destined for the material. use for which it has been expressly The appliance must be positioned so that at designed.
  • Page 10: Installation Standards

    UNICAL refuses all liability for injury to persons, animals or damage to property deriving from not having respected the above mentioned recommendations. In the packaging, in addition to the water heater, you can also find the following contents: - This installation and servicing and user’s manual...
  • Page 11: Water Heater Location

    Instruction for the installer 3.5 - WATER HEATER INSTALLATION 3.4 - WATER HEATER LOCATION Before connecting the water heater the following When selecting the position for the installation of the boiler requirements must be carried out by competent and qualified please comply to the following safety requirements: engineers: a) The system is flushed out with water in order to...
  • Page 12: Mounting Of The Appliance

    Instruction for the installer 3.6 - GAS CONNECTION As a safety measure against gas leaks, DANGER! Unical recommends installing a surveillance The gas connection must be carried out and protective system composed of a gas only by a qualified engineer who will have...
  • Page 13: Ventilation Requirements

    3.9 - SMOKE EVACUATION CONNECTION SMOKE EVACUATION WITH COAXIAL DUCT Ø 60/100 mm We recommend using only original UNICAL flue outlet systems. Type C13 Damages caused by installation errors and The minimum allowed length of the coaxial duct is 0.5 m.
  • Page 14 Instruction for the installer Important: The coaxial duct must have a sloope toward the outside of 2%, in order to allow to the outside the possible condensate. Example 1: LATERAL AIR INTAKE/SMOKE EVACUATION 2° 2° Example 2: REAR AIR INTAKE/SMOKE EVACUATION Minimo 500 2°...
  • Page 15: Electrical Connections

    Before the initial lighting of the water heater it is suggested to technician to check the appliance’s electrical system. check: UNICAL refuses responsibility for any damages arising from failure to earth the boiler correctly. the installation is in conformity with the relevant applica- It is necessary that a qualified technician verifies that the ble standards;...
  • Page 16: User's Instructions

    User’s operating instructions ISTRUCTIONS FOR THE USER 4.1 - PANEL BOARD Ignition button Burner in operation Temperature setting push buttons Temperature value / Error code (+ increases and - reduces) Hot water available D.H.W. flow rate adjuster Fan in operation Drain valve 4.2 - USEFUL SUGGESTIONS AND Adjust the hot water flow rate ‘‘C‘‘...
  • Page 17 User’s operating instructions Adjust the water flow rate through the knob A too low or too high water presure can cause ‘‘C‘‘and the hot water temperature through the an anomalous combustion. button ‘‘B‘‘, according to your own needs. It is In these cases don’t use the water heater up to good to get familiar with the appliance commands when the water pressure returns to the normal...
  • Page 18: Control Panel

    Unical spare parts have to be used. Before proceeding with the maintenance operations, follow strictly the following operations: •...
  • Page 19: Error Codes

    Codes fault ERROR CODES LOCKOUT: The resetting is done by cutting the power, or by closing and opening the hot water tap. The appliance has integral diagnosis system that, in case of STOP: bad operation, allows the immediate indication of the fault is intended ignition not allowed (SERVICE) type on the panel board.
  • Page 20 - info@unical-ag.com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press. Also reserves the right to bring those changes that it will hold necessary to it own products or profits, without jeopardizing its...