Xylem Jabsco Ballast King 22610-9007 Instruction Book
Xylem Jabsco Ballast King 22610-9007 Instruction Book

Xylem Jabsco Ballast King 22610-9007 Instruction Book

Dc flexible impeller pump

Advertisement

Ballast King
DC Flexible Impeller Pump

Advertisement

Table of Contents
loading

Summary of Contents for Xylem Jabsco Ballast King 22610-9007

  • Page 1 Ballast King DC Flexible Impeller Pump...
  • Page 3: Table Of Contents

    Ballast King DC Flexible Impeller Pump Contents Introduction Symbols and using this instruction book Safety Information Unpack and Contents Installation Pump Set-up Pump Assembly and Disassembly Electrical Configuration Footprint Specifications Environmental Protection Product Operation Operating Conditions Permitted Fluids Initial Start-Up Storage and Cleaning Technical Specifications Maintenance, Service and Customer Repair...
  • Page 4: Introduction

    It may not be copied, used or disclosed to others in whole or part for any NOTE: Failure to use this equipment purpose except as authorised in writing by XYLEM. in accordance with the manufacturer’s XYLEM reserves the right to alter, change or operating instructions may compromise modify this document without prior notification.
  • Page 5: Unpack And Contents

    4.0 UNPACK AND CONTENTS - When unpacking the product ensure the correct unit is present. - See ‘pump unit information’ for guidance on unit selection, information is displayed on the product label indicating which model you have. Install overboard discharge well above both Pump Unit Information: static and heeled waterlines.
  • Page 6: Pump Assembly And Disassembly

    - Install the Ballast King pump in accordance to ISO 2. Assembly 10133. - Moisten the new lip seal, and mount the seal - If installed in a vertical position, the motor must with the lip facing towards the impeller. be above the pump head, shown below.
  • Page 7: Footprint Specifications

    - The Waste Electrical and Electronic Equipment Directive (WEEE Directive) is a European Community Directive 2012/19/EU. - Xylem Water Services Limited has identified that there product range comes under Category 6 (Electrical tools) and as such will undertake their responsibilities in line with the above directive and will fulfill their legal obligation by means of joining a compliance scheme.
  • Page 8: Product Operation

    7.0 PRODUCT OPERATION 7.4 STORAGE AND CLEANING 7. 1 OPERATING CONDITIONS - If any pump unit needs to be removed for storage purposes, it must be stored in a cool dry - Maximum ambient temperature is +60 deg. C location (140 deg.
  • Page 9: Maintenance, Service And Customer Repair

    9.0 MAINTENANCE, SERVICE AND CUSTOMER 11.0 PARTS AND ACCESSORIES REPAIR - 22610-9007/ -2007 PUMP (NPT OR BSP PORTS) - The Jabsco Ballast King pump is designed to require minimal amounts maintenance. Item Part Quantity - However it is recommended as good practice to: Number Number - Check that all hose connections are not loose and...
  • Page 10: Ec Declaration Of Conformity

    12.0 EC DECLARATION OF CONFORMITY Declaration of Conformity In accordance with EN ISO 17050-1:2010 In accordance with the following Directive(s): 2004/108/EC Electromagnetic Compatibility 2003/44/EC Recreational Craft Directive 2011/65/EU RoHS Directive (RoHS 2) ISO 8846 Small craft Small craft - Electrical devices - Protection against ignition of surrounding flammable gases hereby declare that: Ballast King 12 V d.c.
  • Page 12 ACCURACY AND COMPLETENESS OF INFORMATION All information in this literature regarding products and services provided by Xylem brands is subject to change without prior notice. Reasonable efforts are taken to ensure the accuracy and integrity of all information provided here, but Flojet & Alcon is not responsible for misprints, out-of-date information, or errors.

This manual is also suitable for:

Jabsco ballast king 22610-2007

Table of Contents