TIPS FOR LONG MEMBRANE LIFE:

1. Replacement of 5 micron carbon block filter at least once every
6 months or when chlorine breakthrough occurs or when water
production is severly reduced. This will ensure good membrane life
and protect the membrane from chlorine damage.
2. Membrane should not be operated at lower than the specified 2:1
concentrate to purified water ratio.
3. Operating reverse osmosis systems on softened feed water greatly
reduces the chances of membrane fouling.
4. Use an optional flush valve after each use of the system to extend
membrane life.
1. It is recommended that you store your RO System in a cool place when
not being used.
2. Your RO System must always be protected from freezing or
temperatures above 113° F (45°C).

TROUBLESHOOTING GUIDE:

Cause
Plugged prefilters
Low water temperature
Low feed pressure
Fouled membrane
SpectraPure
14
STORAGE
Product Water - Low Production Rate
Corrective Action
Replace prefilters
Heat feed water or use higher GPD membrane
Use booster pump or use higher GPD membrane
Replace membrane
Inc.
®
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Eliminator RO BASIC Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Eliminator ro 100-basicEliminator ro 200-basic

Table of Contents