Page 1
• Internal TEST generator on all the outputs • Possibility of disabling color • 2 selectable internal digital filters CONVI 103RR-M 09/05/08 ELPRO Video Labs s.r.l. Via della Praia 4/a FERRIERA di BUTTIGLIERA ALTA (TO) – ITALY Tel.+39 0119348778 - FAX +39 0119348779...
Page 2
Together with the analog outputs, the converter also features 2 equalized, reclocked digital outputs. The CONVI103RR consists of a plug-in and of a separate rear part called CRB103 with the connectors for connections with the external world. The plug-in and the rear part must be inserted in the ELPRO 19" 2RU standard frame, code DVR-MV/RK.
Page 3
Four analog outputs are available. One of these, identified as CV, is always characterized by a PAL or NTSC composite output according to the format selected (dip-switch 8). ELPRO Video Labs s.r.l. Via della Praia 4/a FERRIERA di BUTTIGLIERA ALTA (TO) – ITALY Tel.+39 0119348778 - FAX +39 0119348779...
Page 4
SYNC RGB (synchronism only on RGB) RGB without synchronism ♦ RGB with SYNC on R, G, B. 2.4 Insertion of filters. Dip-switches 5 and 6. The CONVI103RR permits insertion of filters on the output analog signals. DIP-SWITCH FILTER/TEST (filters and test all formats) ♦...
♦ The unit is factory-set as indicated by the sign 3.0 LED INDICATOR LIGHTS The front panel of the CONVI103RR is equipped with two indicator leds. 3.1 Green ON led :switches on when the plug-in is powered correctly and the internal voltages are correct.
2) Make the functional settings on the plug-in as explained in paragraph 2.0 3) From the front of the rack, insert the CONVI103RR plug-in so that its connector is inserted in the edge connector fitted on the rear part of the CRB103.
:230Vac 50Hz Power consumption :5VA Weight :0.3Kg Operating temp.range :0÷45°C Safety :according to EN60065 :according to EN55103-1 and EN55103-2 Mark ELPRO Video Labs s.r.l. Via della Praia 4/a FERRIERA di BUTTIGLIERA ALTA (TO) – ITALY Tel.+39 0119348778 - FAX +39 0119348779...
Page 8
During the warranty period, Elpro will repair the faulty units free of charge. The faulty units must be sent CARRIAGE FREE to the Elpro offices in Turin with a regular accompanying note.