Mounting Instructions 82021 Code-Combi K
3 Assembly
Fig. 3: Exploded view
82021Code-Combi K
Fixing input unit.
Insert the input unit's connecting cable through the door of the safe.
Care must be taken to ensure that the connecting cable is not damaged during installation. Neither the protective cable
casing nor the wiring may be damaged as there would otherwise be a risk of short circuits occurring. The cable should be
safeguarded against damage by means of protective casing or plastic tubing. Care should also be taken to ensure there are
no kinks in the cable or that it is not crushed when it is fixed.
Adjust the plastic input unit and fix with screws. There are two possibilities of fixing the input unit:
1.
From the inside of the door (see Fig. 4) with M4 countersunk screws or
2.
From the outside of the door (see Fig. 5) with M4 cheese head screws
Fig. 4: Fixing from the inner side of the door
Fix lock.
Insert the connecting plug in the lock's socket.
Adjust the lock and fix with screws.
Fit cable cover.
Insert operating shaft in the lock.
Fit operating button on the operating shaft.
Fit cover plate.
4 Final testing
After the fittings have been fixed the handle should be freely movable. When turned 30° the spring action should bring the
handle back into the original position.
The correct functioning of the lock is to be tested in accordance with the operating instructions.
Cable cover
Fig. 5: Fixing from the outside of the door
Connecting sleeve
Door
Connecting cover
Connecting cable
Stand 17.02.2016
Seite 3 von 12