6.3 Safety instructions for maintenance

o Check the mains connection cable for damage from time to time. Never operate the
device when the cable is damaged. A damaged cable must immediately be replaced
by customer service or a qualified electrician to avoid dangers.
o In case of damage or malfunction, please contact your stockist or our customer
service centre. Pay attention to the troubleshooting tips in pt. 7.
o Only a qualified technician and using original spare parts and accessories should
carry out repairs and maintenance of the device. Do not attempt to repair the
device yourself.

7. Possible Malfunctions

Problem
No cooling
Too high of a
temperature in
the device
- 30 -
Cause
• The plug is not connected to
the socket.
• Damaged fuse
• Loss of electrical power
• Faulty thermostat
• Direct sunlight or located near
a heat source
• Improper air circulation in the
device.
• The door is improperly closed
or was left open too long
• The door seal is damaged
• The spacing between the
stored bottles is too small
or there are too many
bottles in the device
• Too low of a temperature
Solution
• Connect the plug to the
socket
• Check the power supply
Check the device by
plugging it into another
socket
• Check the power supply
• Contact a salesperson
• Move the device away
from the heat source
• Ensure a sufficient
distance from walls and
other objects
• Close the door properly
and minimize the time of
opening the door
• Contact a salesperson
• Ensure the correct
distance between the
bottles, remove excess
• Adjust the thermostat
lower
.