Selmo SMART Plus ClassII FP Manual

Selmo SMART Plus ClassII FP Manual

Electronic control for towel radiators

Advertisement

Quick Links

Selmo
"SMART Plus
Electronic control for towel radiators
SMART Plus ClassII FP is an electronic
thermostat for the automatic control of electric
towel radiators. The device is capable of detecting
the room temperature and of keeping it to a
desired value by means of a heating element.
Operative modes: Comfort, Boost,
Standby/Antifreeze, Timer12, Timer24, Fil-Pilote.
• "Fil-Pilote" mode: In "Fil-Pilote" mode the
device is remotely controlled by a central control
system supporting the "Fil- Pilote" standard with
up to six commands: Standby, Comfort, ECO,
antifreeze, Eco-1, Eco-2.
• "Boost" mode: In "Boost" mode the heating
element is activated for a period of 2 hours
independently of the configured temperature. The
temperature is however automatically controlled in
order not to exceed 29°C. At the end of the 2 hours
period, the device returns to "Comfort" mode.
• "Timer" mode: The control system enters into "Boost"
mode for 2 hours; after that it returns into "Comfort"
mode for 22 or 10 hours (period configurable by the
user) and then it enters again into "Boost" mode for 2
hours. This sequence is repeated endlessly.
• "Standby/Antifreeze" mode: In this mode the device goes in standby and powers off
the heating element.
SMART Plus ClassII FP is a certified product:
SMART Plus ClassII FP compliant with the following standards:
-Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W).
-EN 60335-1:2012+A11:2014
-EN 60335-2-43:2003+A1:2006+A2:2008
-EN 61000-3-2:2014 -EN61000-3-3:2013 -EN 62233:2008
-EN 55014-1:2006+A1:2009+A2:2011
Selmo
Electronic
Vi i a Pacinotti, 24 - 35030 Rubano
(PD) Italy- Tel +39.049.8976761, Fax +39.049.8976085 -
Comfort technology division
ClassII FP
Available colours: - White
Rel. 04 – October 2015
"
- Chromed
EN
www.selmo.it

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMART Plus ClassII FP and is the answer not in the manual?

Questions and answers

Summary of Contents for Selmo SMART Plus ClassII FP

  • Page 1 • “Standby/Antifreeze” mode: In this mode the device goes in standby and powers off the heating element. SMART Plus ClassII FP is a certified product: SMART Plus ClassII FP compliant with the following standards: -Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W). -EN 60335-1:2012+A11:2014...
  • Page 2: Technical Characteristics

    Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators ECHNICAL CHARACTERISTICS Product Electronic control for towel radiators Applications Towel radiators Insulation class Class II with Fil-Pilote IP level IP44 Temperature setting Digital Selectable temperature range 7°C ÷...
  • Page 3: Risk Of Electric Shock

    Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators WARNING RISK OF ELECTRIC SHOCK! Disconnect power supply before proceeding with installation. Preserve with care the present instruction sheet and read carefully before using the device.
  • Page 4 Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators Installation Guide To be used by installer only Disconnect the device from power supply before proceeding with installation. • Protect the device with a 30mA RCD circuit breaker.
  • Page 5 Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators Accessory: To allow a mixed usage of the SMART device, connect the T-piece to the towel radiator, insert the SMART device into the vertical manifold of...
  • Page 6 Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators User Manual “Comfort Bar”: Indicates the Heating element selected temperature and further accessory information [On/Standby] button 1/2" GAS thread for fastening on the radiator [+] and [-] buttons:...
  • Page 7 Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators Comfort bar 20°C 21.5°C* 18.5°C* 23°C 17°C 24.5°C* 26°C 15.5°C* 27.5°C* 14°C 29°C 7°C * Blinking LED On/Standby Press the [On/Standby] button to turn on the device or to activate the “Standby”...
  • Page 8: Temperature Setting

    Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators Temperature setting: This function allows the selection of the “comfort” mode temperature of the “Fil-pilote”. The temperature is set through the [+] and [-] buttons to one of the following temperature values: 7°C;...
  • Page 9 Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators “Boost” mode : Press the [Boost/Timer] button to activate this operative mode. This mode activates the heating element to the maximum power for 2hrs (for safety reasons the maximal temperature is limited to 29°C).
  • Page 10: Key Lock Function

    Selmo Comfort technology division “SMART Plus ” ClassII FP Electronic control for towel radiators Boost/Timer LED functioning summary “Boost” mode active. The heating element is powered for 120 minutes (temperature of the Blinking red radiator automatically limited to 29°C). Blinking Green “Boost” function active in Timer24 mode. The heating element is powered for 120 minutes (temperature of the radiator automatically limited to 29°C).

Table of Contents