Installation and Operations Manual — Model 400E Series
SAFETY DEVICES (ALL) I6
STOP (NORMALLY CLOSED) I7
LOCK PIN DOWN (450) I13
2.5.4
Terminate field output wiring for optional components.
Control Panel Indicators
GREEN INDICATOR Q8
OPTIONAL DEVICES
Loop Detector – One loop detector and socket come pre-wired for use as a safety. The
loop wires connect to terminals 7 & 8 on the loop detector socket. The safety loop is
wired into the safety input in the ECU.
IR Beam – It is suggested that infrared safety beams are used as an additional layer of
safety. An IR beam receiver's Normally Open output may be wired into the safety input
in the ECU.
Edge Detector – A closing edge detector's receiver may be wired into the safety input in
the ECU, and an optional opening edge detector's receiver may be wired into the
Backsensor input in the ECU.
Card Reader – A 3
rd
open the gate. A normally open output on such a device may be wired to the open input
in the ECU.
B&B ARMR
A Division of B&B Roadway and Security Solutions
Description
OPEN I1
CLOSE I2
LOCK PIN UP (450) I3
CLOSED LIMIT A I4
OPEN LIMIT A I5
ECO I9
ECO RESET I10
CLOSED LIMIT B I11
OPEN LIMIT B I12
BACK SENSOR I14
Traffic Lights
Common 120VAC Neutral (white
GREEN/AMBER Q6
RED Q7
0V 0V (black terminal blocks)
RED INDICATOR Q9
ECO Q10
party entry access device such as a badge reader may be used to
Terminal
Block
Terminal Block
terminal blocks)
Terminal Block
13
0400E-9001 Rev J