Download Print this page

Dimplex EvoRad Series Instruction Manual page 5

Advertisement

Manual Operation
Repeatedly press the ' ' button until the manual mode
is visible on the LCD and confirm the mode selection by
pressing ENTER. Use the arrow keys to select the desired
heat setting (see Operational modes for heat setting
details) and confirm the selection by pressing the ENTER
key. The desired temperature can be adjusted at any point
during the Manual mode operation, see Setting the Desired
temperature.
Auto mode Operation
Repeatedly press the ' ' button until the Auto mode is visible
on the LCD (see Fig.7) and confirm the mode selection by
pressing ENTER. The heater will operate as per the pre-
programmed time and temperature profile (see - Setting
the Timer Profile).
Note: if no timer profile has been set it will not be possible to
select 'Auto' mode, it is necessary to set up a time program
before Auto mode can be selected.
During Auto mode operation the LCD display will show the
current heat status, the active programme segment, the
time for the next status change, the heat setting and the
set temperature (see Fig.9).
Boost mode Operation
Repeatedly press the ' ' button until the Boost mode
is visible on the LCD (see Fig.8) and confirm the mode
selection by pressing ENTER. Once the boost mode is
activated it will be necessary select the boost period, there
are three periods available to choose from, 30 minutes, 1
hour and 2 hours. Use the arrow keys to select the desired
boost period and confirm the selection using the ENTER
key. The default heat setting is ECO mode and the set
temperature is 25˚C. The set temperature can be adjusted
if desired, see Setting the Desired temperature. When
the boost mode is active the LCD display will show the
boost mode, timer period selected and the desired set
temperature. The time display will toggle between the
current time and time remaining for the selected boost
period.
Frost protection mode
The appliance has a frost protection mode. This setting is
useful in areas such as garages to assist in the prevention
of frost damage. In Manual mode, if the thermostat is set
to its minimum setting '5°C', the heater will cycle ON and
OFF to maintain a temperature of approximately 5°C and
help protect against frosty conditions. The frost protection
symbol
will be displayed on the LCD display when frost
protection mode is activated.
Indicator Neons
Mains On Neon: The mains neon, (see Fig. 1), remains
illuminated when the power is supplied to the product. Note:
This does not indicate whether the heating elements are on.
Heat Neon: Heat neon remains on when the heating
element is active. Once the desired temperature is reached
and the element turns off, the heat neon will indicate this
by remaining off.
Bluetooth Neon: The Bluetooth neon will remain illuminated
while successfully paired to another device.
Setting the Desired Temperature
The desired temperature can be set using the ' ' or '
' keys. The temperature can be set from 5˚C to 30˚C and
this will be shown on the display. When the temperature
is reached the heater will automatically switch OFF. If the
ambient temperature drops the heater will come on again
automatically.

Advertisement

loading

This manual is also suitable for:

Evorad2btaEvorad2bt