Wilo SiClean Series Installation And Operating Instructions Manual
Wilo SiClean Series Installation And Operating Instructions Manual

Wilo SiClean Series Installation And Operating Instructions Manual

Advertisement

Quick Links

Pioneering for You
Wilo-SiClean
de Einbau- und Betriebsanleitung
en Installation and operating instructions
fr
Notice de montage et de mise en service
nl
Inbouw- en bedieningsvoorschriften
4 192 808-Ed.01 / 2015-04-Wilo

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SiClean Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilo SiClean Series

  • Page 1 Pioneering for You Wilo-SiClean de Einbau- und Betriebsanleitung en Installation and operating instructions Notice de montage et de mise en service Inbouw- en bedieningsvoorschriften 4 192 808-Ed.01 / 2015-04-Wilo...
  • Page 2 Fig. 1: "A" Fig. 2: 230V...
  • Page 3: Table Of Contents

    Commissioning ............................ 18 General preparation and checking ........................19 Filling, ventilation..............................19 Starting the installation ............................19 Maintenance ............................19 Emptying ................................19 Faults, causes and remedies ......................20 Spare parts ............................21 Disposal ..............................21 Installation and operating instructions Wilo-SiClean...
  • Page 4: General

    CAUTION! There is a risk of damage to the product/unit. ’Caution’ implies that damage to the product is likely if this information is disregarded. NOTE: Useful information on handling the product. It draws attention to possible problems. WILO SE 04/2015...
  • Page 5: Personnel Qualifications

    Work to the product/unit must only be carried out when at a standstill. It is mandatory that the procedure described in the installation and oper- ating instructions for shutting down the product/unit be complied with. Installation and operating instructions Wilo-SiClean...
  • Page 6: Unauthorised Modification And Manufacture Of Spare Parts

    (e.g. sand) increase pump wear. Pumps without an Ex- rating are not suitable for use in potentially explosive areas. • The correct use of the pump/system also includes following these instructions. • Any other use is considered to be incorrect use. WILO SE 04/2015...
  • Page 7: Product Information

    Description and function General description The Wilo-SiClean is a compact unit delivered ready to be assembled. To be attached to wall, or to floor depending on model. Connections have to be made for suction and discharge and also for the power mains.
  • Page 8: Function Of The Siclean System

    Provide an automatic water supply because of the loss of water due to sludge disposal. To maintain pressure and ensure water feed you can install a pres- sure-maintaining system Wilo-WEH/WEV. Installation • Install the SiClean in a room which is easily accessible, well ventilated, frost-proof and protected against rain.
  • Page 9: Assembly

    (i.e according to the local regulations and circum- stances). Commissioning We recommend that the initial commissioning of SiClean is performed by the nearest Wilo customer service agent or ask your central cus- tomer service department. Installation and operating instructions Wilo-SiClean...
  • Page 10: General Preparation And Checking

    DANGER! Risk of burns when body parts come into contact with the pump! Depending on the pump or system operating conditions (fluid tem- perature), the entire system can become very hot. • Keep a safe distance during operation! WILO SE 04/2015...
  • Page 11: Faults, Causes And Remedies

    • Keep a safe distance during operation! • In the case of high water temperatures and system pressures, allow the pump/system to cool down before working on it. • Always wear protective clothing and gloves when working. Installation and operating instructions Wilo-SiClean...
  • Page 12: Spare Parts

    If the fault cannot be remedied, please contact the trade or your near- est Wilo-After-Sales Service or agent. Spare parts Spare parts must be ordered via a local specialist retailer and/or Wilo Customer Service. To avoid queries and incorrect orders, all data on the ratingplate should be submitted with each order.
  • Page 13 Division Pumps and Systems Person authorized to compile the technical file is: Quality Manager - PBU Systems Personne autorisée à constituer le dossier technique: WILO SALMSON FRANCE SAS 80 Bd de l'Industrie - BP 0527 F-53005 Laval Cedex Dortmund, 19.02.2015 WILO SE Nortkirchenstraße 100...
  • Page 14 Kompatibbiltà elettromanjetika - Direttiva 2004/108/KE Elektromagnetna kompatibilnost - smjernica 2004/108/EZ Elektromagnetna kompatibilnost - direktiva 2004/108/EZ b'mod partikolari: primijenjene harmonizirane norme, posebno: primenjeni harmonizovani standardi, a posebno: ara l-pa na ta' qabel vidjeti prethodnu stranicu vidi prethodnu stranu WILO SE Nortkirchenstraße 100 44263 Dortmund Germany...
  • Page 15  *DQJVHR %XVDQ Australia Burton Upon Trent 101300 Beijing :,/2 5RPDQLD VUO  9™[Mª T +82 51 950 8000 WILO Australia Pty Limited DE14 2WJ T +86 10 58041888  &RP &KLDMQD T +46 470 727600 ZLOR#ZLORFRNU Murrarrie, Queensland, T +44 1283 523000...
  • Page 16 WILO SE Nortkirchenstraße 100 D-44263 Dortmund Germany T +49(0)231 4102-0 F +49(0)231 4102-7363 wilo@wilo.com Pioneering for You www.wilo.com...

Table of Contents