Instrument Cluster; Odometer Write Procedure - Mazda 3 Facelift 2006 Training Manual

Table of Contents

Advertisement

Instrumentation/Driver Info

Odometer Write Procedure

An odometer write procedure for the instrument cluster has been added. When
configuring a new instrument cluster with M-MDS, the total mileage logged in the old
cluster is automatically uploaded to the new cluster. To do this, connect M-MDS to the
vehicle and select the option Toolbox→Module Programming→Programmable
Module Installation→IC.
The odometer write procedure can only be conducted once. However, the new
instrument cluster must display less than 100 km for the mileage data to be uploaded. If
a cluster with 100 km or more is configured, M-MDS will display an error message after
configuring, indicating that the procedure failed. In this situation, all data other than the
mileage will have been uploaded into the new instrument cluster, so that the
configuration is actually successful.
In order to upload the mileage data to a new instrument cluster with an odometer setting
of 100 km or more, perform the odometer write procedure after completing the
instrument cluster configuration. To do this select the option Toolbox→Module
Programming→Programmable Parameters→Odometer Write. During this procedure
M-MDS will request the user to input As-built data (VIN and Vehicle Data).
NOTE: Do NOT delete the M-MDS session until the odometer write procedure is completed.
Otherwise it is not possible anymore to upload the mileage data to the new

instrument cluster.

NOTE: In case the old instrument cluster is electrically damaged and therefore the
configuration data cannot be read, the odometer write procedure cannot be
performed.