Short manual 021690/10/14/short CLIMA SENSOR US 4.920x.00.00x ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com...
Page 2
Safety Instructions • Before operating with or at the device/product, read through the operating instructions. This manual contains instructions which should be followed on mounting, start-up, and operation. A non-observance might cause: - failure of important functions - endangerment of persons by electrical or mechanical effect - damage to objects •...
Page 3
3. Installation of the CLIMA SENSOR US Attention: The working position of the CLIMA SENSOR US is vertical (plug connection underneath). During mounting, de-mounting, transport or maintenance of the CLIMA SENSOR US please make sure that no water gets into the instrument base or plug.
Page 4
30 mm in length. The inside diameter of the tube socket must be at least 30 mm as the electrical connection of the CLIMA SENSOR US is carried out at the bottom of the device. After connection the CLIMA SENSOR US is then mounted on the tube or mast socket.
Page 5
2.2 Electrical installation / Start-up 1. The connection of the ClimaSensor US to the interface module and power supply unit differs, depending on the instrument variant. You have to distinguish between the connection types full-duplex and half-duplex with cable 16pole or resp. 8pole. Information on the duplex-mode are given by parameter DM on the supplemental sheet “Factory settings”...
Page 6
13. By pressing the button “Terminal” a window is opened, where individual commands can be sent, and parameters can be changed. See also the online help of the program “Thies Device Utility.exe”. The program supports both the “Thies”- and the MODBUS-command interpreter.
Page 7
Connection Diagram of 4.920x.00.000 in Full-duplex Mode and 16pole Connecting Cable Geräte - Konfiguration Clima Sensor US NHTFB , 4. 9200. 00. 000 Clima Sensor US ..siehe Bestell - Nr. Ausgang / Output : 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 Bedienungsanleitung 4.
Page 8
Connection Diagram of 4.9200.00.000 in Full-duplex Mode and 8pole Connecting Cable Clima Sensor US NHTFB Geräte - Konfiguration Clima Sensor US ..4. 9200. 00. 000 siehe Bestell - Nr. 4. 920x. 00. 000 Bedienungsanleitung Vollduplex / Full duplex Clima Sensor US TFB Instument - Configuration 4.
Page 9
Connection Cable of 4.920x.00.000 / 001 in Half-duplex Mode and 8pole Connection Cable Clima Sensor US NHTFB Geräte - Konfiguration Clima Sensor US ..4. 9200. 00. 000 siehe Bestell - Nr. Bedienungsanleitung 4. 920x. 00. 000 Clima Sensor US TFB...
Page 10
Installation of the USB/RS485 Interface Converter 9.1702.40.000 For the installation of the USB/RS485 interface converter please proceed as follows: 1. Insert the included CD into the CD-ROM drive. 2. Put the USB-plug of the RS485 converter into the provided socket of the PC. 3.
Technical Data Measuring range 0.01 m/s...60 m/s Wind speed Scaling of analogue output freely selectable ≤ 5 m/s: ± 0.3 m/s (rms - mean over 360°) Accuracy 5...60m/s: ± 3 % of measured value (rms - mean over 360°) Resolution 0.1 m/s: in telegrams 1, 2, 3, 5, 6 0.01 m/s: in telegram 14 Measuring range...
Page 13
to 2 min in increments of 100 msec freely selectable Output rate One per 10 msec to one per 60 seconds in increments of 1 msec freely selectable Protocol ASCII- Thies-Format and MODBUS RTU Electrical outputs 0... 10 V Data output analogue Electrically isolated from supply Permissible burden on voltage output: ≥...