1.
Open Box and Verify Contents
• Quantity 1 - ALPHA 4000RGB PoE MNS LED
sign
• Quantity 2 - Mounting Bracket
• Quantity 4 - ¼-20 x ½ Hex Head Cap Screws
• Quantity 1 - Optional RS485 Ferrite
• Quantity 1 - ½ - Inch NPT Liquid Tight Strain
Relief Cord Grid
Quantity 1 - .41-inch Liquid Tight Strain
Relief Cord Grip for optional RS485
2.
It is recommended the power over Ethernet (PoE)
connection to LED Sign be made prior to installing
the mounting bracket to the rear of the sign.
3.
Begin by removing the (4) 6-32 tamper proof
screws holding the removable cover for the
Ethernet connection.
• T15 Pin in Torx Driver is required (not supplied).
• Take care not to lose screws.
• See: Back View Cover Removed.
4.
Choose the ½ inch trade knockout to remove for
your installation location. Two are provided.
Exercise caution when removing either knockout
so as to avoid the knockout blank unintentionally
entering the inside of the unit. No other entry holes
may be added to the sign or warranty will be
voided.
• Ethernet wiring, conduit, conduit fittings for
making connections to rear of LED sign are not
supplied.
• Use appropriate conduit fittings and connections
to route Ethernet wiring into the LED sign
termination compartment.
• One ½ - inch NPT liquid tight strain relief cord grip and locknut is provided as an alternative to using conduit.
5.
Wiring method shall be in accordance with:
• In Canada, CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32;
• In the United States, the National Electrical Code, NFPA 70, and the National Fire Alarm and signaling Code, NFPA
72;
6.
Make the customer connection to the sign.
• Insert cable (not provided) into the Ethernet connection port.
• Attach provided ferrite around the Ethernet cable (ferrite must be attached within the sign).
7.
Replace the removable cover using the (4) 6-32 tamper proof screws.
• T15 Pin in Torx Driver is required (not supplied).
• Torque to a maximum of 10 lb-in.