MDKE9 Smart Operating Panel
User Guide
A01
Data code 19010628

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MDKE9 Series and is the answer not in the manual?

Questions and answers

YUVARAJ
March 18, 2025

HOW TO MOUNT IN PANEL

Summary of Contents for Inovance MDKE9 Series

  • Page 1 User Guide MDKE9 Smart Operating Panel User Guide Data code 19010628...
  • Page 2: Preface

    USB mass storage functions. This user guide describes the correct use of the MDKE9 series smart operating panel, including safety precautions, product information, installation, and wiring, function and application, maintenance and repair.
  • Page 3: Table Of Contents

    Contents 4.3.1 Fault Viewing ......... 21 4.3.2 Modified Parameters ...... 21 4.3.3 "Shortcut" Interface ......22 Preface ............1 4.3.4 History Faults ......... 22 Chapter 1 Safety Instructions ..... 3 4.4 Equipment Operating ......22 1.1 Safety Disclaimer ........3 4.4.1 Commission ........
  • Page 4: Chapter 1 Safety Instructions

    1 Safety Instructions Chapter 1 Safety Instructions 1.1 Safety Disclaimer 1) Read and comply with the safety instructions during installation, operation, and maintenance on the equipment. 2) To ensure the safety of humans and the products, follow the marks on the products and all the safety instructions in this document.
  • Page 5 1 Safety Instructions Storage and Transportation Caution Store this equipment based on the storage and transportation requirements on humidity and tem- ◆ perature. Avoid transporting the equipment in environment such as water splashing, rain, direct sunlight, high ◆ voltage, strong magnetic field, and strong vibration. Avoid storing the product for more than 3 months, long-term storage shall require stricter protection ◆...
  • Page 6 1 Safety Instructions Wiring Danger Do not allow non-professionals to perform product installation, wiring, maintenance, inspection or ◆ parts replacement. Never perform wiring at power-on. Failure to comply may result in electric shock. ◆ Cut off all power supplies before wiring. Wait at least 10 minutes after power-off so that residual ◆...
  • Page 7 1 Safety Instructions Warning Prevent metal or other objects from falling into the device during operation, failure to comply may ◆ result in equipment damage. Never use contactors to start or stop the equipment. Failure to comply may result in damage to the ◆...
  • Page 8: Safety Signs

    1 Safety Instructions 1.4 Safety Signs To guarantee safety operations and maintenance of the equipment, follow the safety stickers on the equip- ment and products. Do not stain or remove the safety signs. Instructions of safety signs are as follows: Safety signs Instructions ◆...
  • Page 9: Chapter 2 Product Information

    MD200 series, MD310 series, MD500 series, MD500E series, and MD290 series. 2.1 Nameplate Figure 2-1 Nameplate Nameplate Model MODEL: MDKE9 S/N: 01040037H500025 Suzhou Inovance Technology Co.,Ltd. 2.2 MDKE9 Dimensions Figure 2-2 MDKE9 dimensions (Unit: mm) 26.4 MDKE9 - 8 -...
  • Page 10: Components

    2 Product Information 2.3 Components Figure 2-3 MDKE9 Components Fixing hook MDKE9 Fastening screw RJ45 interface Screen Nameplate Keys Battery cover Indicator Fastening screw connector ● USB connector Connect the MDKE9 to a PC via a USB cable for data exchange after connection, it can work in USB disk mode to read/write the MDKE9 SD card through PC.
  • Page 11: Key Introduction

    2 Product Information 2.4 Key Introduction 2.4.1 Keys and Functions Table 2-1 Keys and functions Name Function Left To return or cancel. Right To select or confirm. To quickly enter the device list Shift On some interfaces, you are not allowed to switch over the devices and the key is invalid.
  • Page 12: Indicator Status

    2 Product Information 2.5 Indicator Status The status indicator is used to indicate whether a fault or alarm exists. Table 2-3 Indicator status status Indicator state Demonstration Meaning Steady on in green The device runs normally. Flashing in green Data is transferring between the MDKE9 and PC via USB. Communication between the MDKE9 and the device is normal, but Steady on in red the device is faulty.
  • Page 13: Chapter 3 Installation And Wiring

    Chapter 3 Installation and Wiring The MDKE9 is suitable for multiple Inovance’s AC drives. This user guide takes M310 as the example to describe the installation and wiring of the MDKE9. Refer to the corresponding user guide for details if the MDKE9 is installed on other AC drives.
  • Page 14: Connect Mdke9 With Pc

    3 Installation and Wiring 3.2 Connect MDKE9 with PC The mini-B type USB connector of the MDKE9 is to connect the PC, the USB cable length cannot exceed 3 m. The communication protocol is USB2.0 between the MDKE9 and the PC. 1)...
  • Page 15: Install Mdke9 On The Cabinet Door

    3 Installation and Wiring 3.3 Install MDKE9 on the Cabinet Door When installing the MDKE9 panel on the cabinet door, install the panel base first (optional), the installation procedures are as follows: Purchase code Model Description 01040022 CP600-BASE1 Panel base installation package 1)...
  • Page 16 3 Installation and Wiring 3) Take the MDKE9 out. Press clip in figure 3-5 with the index finger and middle finger to release the MDKE9, then pull the upper end of the MDKE9 out of the base slot. Figure 3-6 Sheet metal slot dimensions Figure 3-7 Base mounting hole size 27.5 27.5...
  • Page 17: Chapter 4 Functions And Applications

    4 Function and Application Chapter 4 Functions and Applications 4.1 Summary Figure 4-1 MDKE9 menu structure diagram Parameters Group Parameter Alarm Change Fault records Shortcut History alarm Adjust Device Control Step Ctrl Menu Login Authority Manufacturer Protect time Backlight Contrast System set Date/Time Language...
  • Page 18: Main Interface

    4 Function and Application 4.1.1 Main Interface Main interface: used to monitor signals. The interface is as below: Figure 4-2 Main interface Device status Current control device Stop Inverter 01 Running frequency 0.00 Hz 02 Frequency reference 50.00 Hz 03 Bus voltage 298.6 V 18:10:21 Menu...
  • Page 19: Help

    4 Function and Application 4.1.2 Help Figure 4-4 Help icon display demonstration Stop Inverter F1-03 Rated motor current 25.00A • F1-04 Rated motor frequency 50.00HZ F1-05 Rated motor speed 1460 rpm Back 1 8 : 0 0 : 0 2 Select Help In some particular menus and interfaces, you can press...
  • Page 20: Connecting To The Pc

    4 Function and Application 4.1.6 Connecting to the PC The MDKE9 is connected to the PC via a USB cable: USB mass storage mode You cannot operate the MDKE9 when it is connected to a PC. Connecting steps: 1) Use one end of the USB cable to plug into the MDKE9 USB interface, the other end connect to USB interface of PC 2)...
  • Page 21 4 Function and Application 1) Modifying digit parameters to set F1-04 to 40.00Hz, that is taking the rates frequency of 40.00 Hz as an example. The setting steps are as follows: Figure 4-5 Example of modifying digit parameters Inverter Stop Inverter Stop Inverter...
  • Page 22: Status Monitoring

    4 Function and Application 4.2.2 Add the Parameter to the"Shortcut" Interface In parameter list, move the cursor to the parameter to be added and hold down the for 1.5s. you can add 20 parameters to the shortcut interface and a prompt will appear to indicate whether the parameter is added successfully or not.
  • Page 23: Shortcut" Interface

    4 Function and Application 4.3.3 "Shortcut" Interface All user-defined parameters are listed on shortcut page, for detailed adding procedure, see "4.2.2 Adding Parameters to the "Shortcut" interface. On the shortcut interface, move the cursor to the function code to be deleted, hold down for 1.5s to delete the function code from the short cut interface.
  • Page 24: Authority

    4 Function and Application 4.5 Authority You can login the equipment via panel operating on Authority Management interface. 4.5.1 Login Table 4-6 Login description Task Action Logging into the system Open “menu”-”authority management”-”logging on” You have to log in to the MDKE9 before using the following functions under system control: ●...
  • Page 25: System Operation

    4 Function and Application Task Action Change the audio setting Open “menu”-”system setting”-”language selection” Change time Open “menu”-”system setting”-”date/time” Set backlight light off time Open “menu”-”system setting”-”protect time” Check panel version Open “menu”-”system setting”-”about” 1) Set Protection time The backlight might go off when there is no operation for a period of time. The unit of time is minute, support up to 99 minutes protect time setting.
  • Page 26 4 Function and Application Inverter Inverter Stop Stop Inverter Stop 03 Device Control • 01 Parameter Copy • 01 Read Parameter 04 Authority 02 Update SOP 02 Write Parameter 05 System Set • 06 System Control Back 18:00:02 Select Back 18:00:02 Select Back...
  • Page 27: Device Burning

    4 Function and Application ① Press to select the target device; ② Enter "write parameter" menu, then press to select the already read parameter file; ③ In the copy mode interface, select the parameter copy mode you need; ④ Wait until the parameter download completes. Figure 4-12 Example of write parameters Inverter Select File...
  • Page 28: Update Device

    4 Function and Application ● After completion, copy the burning file to the SD card SYS/PROGRAM directory; Enter the device burning menu after login ② ③ Select the files to be burnt in the file list; Press the "right" key after confirming the file information is correct in the burning file ④...
  • Page 29 4 Function and Application Wait for the panel to complete restart, and the file burning procedure ends. ⑤ Figure 4-16 Example of program update processing Select File • factorys.bin MDKE9-20170428-01s.bin Device will reboot and update Back Select Copy the update file from the PC to X: \SYS\PROGRAM. For details of the storage method of Note the SD card file, see “5.3 SD Card Replacement”.
  • Page 30: Chapter 5 Maintenance And Repair

    5 Maintenance and Repair Chapter 5 Maintenance and Repair 5.1 Daily and Periodical Inspection Table 5-1 Carry out daily and periodic inspection as follows: Type Cycle Inspection Items Check the ambient temperature, humidity, dust, foreign objects. Check whether there is abnormal noise Check whether the USB connector cover and the battery cover are installed properly.
  • Page 31: Sd Card Replacement

    5 Maintenance and Repair Step 3: Place the battery into the clip (A side) first and Step 4: Put the battery cover back then press other end (B side) of the battery. 5.3 SD Card Replacement Figure 5-2 Replace the SD card Step 1: Use a slotted screwdriver or fingers to remove Step 2: Push the metal cover towards the unlock the battery cover.
  • Page 32 5 Maintenance and Repair Step 5: Put the battery cover back. Note Plug and play is not supported. Replace the SD card when the MDKE9 is powered off. - 31 -...
  • Page 33: Revision History

    Revision History Revision History Date Version Change Description Oct. 2017 First issue. Apr. 2019 Updated the cover. - 32 -...
  • Page 34 Service Hotline: 400-777-1260 http: //www.inovance.com Suzhou Inovance Technology Co., Ltd. Add.: No. 16 Youxiang Road, Yuexi Town, Wuzhong District, Suzhou 215104, P.R. China Tel: +86-512-6637 6666 Fax: +86-512-6285 6720 Service Hotline: 400-777-1260 http: //www.inovance.com Copyright   Shenzhen Inovance Technology Co., Ltd.