Emerson Fisher 846 Instruction Manual page 7

Current-to-pressure transducers
Hide thumbs Also See for Fisher 846:
Table of Contents

Advertisement

Instruction Manual
Form 5739
February 2002
Model
3311/0846
Code
D
R
Code
S
M
Code
1
2
3
4
Code
J
K
L
M
W
H
Code
1
2
Code
B1
B2
B3
B4
F2
F3
G1
G2
G7
G8
G9
GA
GB
GE
GF
GG
P1
(3)
R1
(1)
A1
Q4
K5
C6
I1
N1
(2)
E9
K7
(2)
EG
IG
1. Not available with stainless steel housing
2. Hazardous location approval options E9 and EG are currently not available on multirange performance units.
3. With option R1, the Type 846 and Model 3311 circuit board contains the Remote Pressure Reading feature. The Remote Pressure Reading jumper is placed in the ON position prior
to shipment.
Companion Product: Model 272 Field Calibrator
The Rosemount Model 272 Field Calibrator can be
used to calibrate the I/P transducer. A
battery-operated, portable calibrator designed for
Table 1-3. Model Number Table
Reverse—Output changes inversely with input
Standard (Typical Output: 3–15 psi; Wide rangebility betweeen 1 and 18 psi)
Multirange (Typical Outputs: 3–27 psi, 6–30 psi, and 5–25 psi; Wide rangebility betweeen 0.5 and 33.0 psi)
Specify (Consult factory for other input ranges between 4–20 mA and 10–50 mA)
3–15 psi for direct action (15–3 psi for reverse action)
0.2–1.0 bar for direct action (1.0–0.2 bar for reverse action)
0.2–1.0 kg/cm
3–27 psi for direct action (27–3 psi for reverse action) Multirange performance units only
6–30 psi for direct action (30–6 psi for reverse action) Multirange performance units only
Specify (Consult factory for other calibration requirements; minimum span is 6 psi for direct and 11 psi for
Universal mounting bracket, epoxy painted carbon steel, carbon steel nuts and bolts
Universal mounting bracket, epoxy painted carbon steel, stainless steel nuts and bolts
316 SST universal mounting bracket, SST nuts and bolts for use with SST housing
316 SST universal mounting bracket, SST nuts and bolts for use with aluminum housing
SST Supply gauge (0–60 psi/0–400 kPa/0–4 bar)
SST Output gauge (0–60 psi/0–400 kPa/0–4 bar)
Attach all applicable options at the factory (i.e., filter-regulator and gauges)
Factory Mutual (FM) explosion-proof and intrinsic safety approval
Canadian Standards Association (CSA) explosion-proof and intrinsic safety approval
BASEEFA/CENELEC intrinsic safety certification
Standards Association of Australia (SAA) flameproof intrinsic safety, and Type n certification
Typical Model Number: 3311 D S 1 J 1 B1
Product Description
Current-to-Pressure Transducer
Action
Direct—Output changes directly with input
Performance
Input
4–20 mA dc
4–12 mA dc
12–20 mA dc
Output
2
for direct action (1.0–0.2 kg/cm
reverse-acting units)
Electrical Connections/Housing Material
1/2–14 NPT/Aluminum
1/2–14 NPT/316 stainless steel
Options
Filter-regulator, SST bolts
SST Filter-regulator, SST bolts
Supply gauge (0–60 psi/0–400 kPa/0–4 bar)
Output gauge (0–30 psi/0–200 kPa/0–2 bar)
Supply gauge (0–60 psi/0–4 kg/cm
Output gauge (0–30 psi/0–2 kg/cm
Output gauge (0–60 psi/0–400 kPa/0–4 bar)
SST Output gauge (0–60 psi/0–4 kg/cm
SST Supply gauge (0–60 psi/0–4 kg/cm
Output gauge (0–60 psi/0–4 kg/cm
Module Cover with Multiple Ports
Remote pressure reading feature
Calibration data sheet
BASEEFA Type N certification
ISSeP/CENELEC flameproof certification
Russian GOST flameproof certification
Russian GOST intrinsic safety certification
field use, the Model 272 features an adjustable 4–20
mA range, and selectable indication/simulation
modes. See product data sheet 00813-0100-4372.
Introduction
2
for reverse action)
2
)
2
)
2
)
2
)
2
)
1–7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fisher 3311

Table of Contents