Download Print this page
Quincy lab 140-1 Series Operating Manual

Quincy lab 140-1 Series Operating Manual

General purpose incubators

Advertisement

Quick Links

Quincy Lab, Inc.
Model 12-140-1
SPECIFICATIONS
Interior Dimensions
INCHES W x H x D
Exterior Dimensions
INCHES W x H x D
Weight (lbs)
Cubic Foot Capacity
Standard Electrical: 230 volts, 50/60 Hz
Temperature Range
Common Unit Specifications
Operating Environment: Indoor use, altitude to 6,500 ft. (2,000m) Installation Category II,
Storage Temperature:
Approvals:
Compliance:
Common Unit Construction
Exterior: Powder-Coated Steel
Insulation: Fiberglass
Thermo-control: Bi-Metal
Issue Rev A 0309
Copyright Quincy Lab Inc. 2009
Model Series 140-1 & 180-1 (230 V )
MODEL
10-140-1
12x10x10
31x25x25
(CM) W x H x D
13x15x11
33x38x28
(CM) W x H x D
19 lbs
120
WATTS
Pollution Degree 2, ambient temperature 10
80% RH maximum.
o
-10
C/14
Underwriter's Laboratory Listed, Laboratory Equipment, C/UL
United States/Canadian. E212550 (115VAC models only)
UL Standard 61010-1, IEC 61010-1, 2nd Edition.
Quincy Lab Inc. 1925 N. Leamington Ave.
General Purpose Incubators
OPERATING MANUAL
MODEL
12-140-1
18x16x12
46x41x30
19x21x13
48x53x33
33 lbs
235
o
o
o
F to 70
C/158
F, 70% RH maximum.
Interior: Aluminum
Door: 140-1: Acrylic, 180-1: Steel Insulated
Heater: Resistive-Tubular Incoloy
Chicago, Illinois 60639 1-800-482-HEAT (4328)
Model 10-180-1
MODEL
MODEL
12-180-1
10-180-1
12x10x10
18x16x12
31x25x25
46x41x30
13x15x11
19x21x11
33x38x28
48x53x33
19 lbs
33 lbs
270
385
o
o
o
C/50
F to 35
C/95
o
F,
PAGE 1

Advertisement

loading

Summary of Contents for Quincy lab 140-1 Series

  • Page 1 Exterior: Powder-Coated Steel Interior: Aluminum Insulation: Fiberglass Door: 140-1: Acrylic, 180-1: Steel Insulated Thermo-control: Bi-Metal Heater: Resistive-Tubular Incoloy Issue Rev A 0309 PAGE 1 Quincy Lab Inc. 1925 N. Leamington Ave. Chicago, Illinois 60639 1-800-482-HEAT (4328) Copyright Quincy Lab Inc. 2009...
  • Page 2 Safety Precautions Read Operating Instructions Thoroughly Prior to Operation Read Operating Instructions thoroughly prior to operation. Use only a grounded outlet that is rated for your models' electrical requirement. Do not modify the oven or factory control settings to operate the oven above the stated maximum operating temperature.
  • Page 3 General Operation Push the illuminated power button. Rotate the thermostat knob clockwise to approximately the number 6 on the dial. The heat cycle light will illuminate to indicate that the heating element is energized. Observe the thermometer. When the desired temperature is reached, slowly turn the thermostat knob counter clockwise until the heat cycle indicator turns off.
  • Page 4 Chicago, Illinois 60639 Limited Warranty Quincy Lab, Inc. warrants to the original purchaser that this product will be free from defects in material and workmanship under normal use throughout the warranty period. The standard warranty period for this instrument is 18 months, (3-year coverage on the heater element), from date of shipment.

This manual is also suitable for:

10-140-1180-1 series12-180-110-180-112-140-1