Maintenance Of The Unit; Cleaning; Replacement Of The Driving Belt; Fuses - BAQ kaloMAX Manual

Table of Contents

Advertisement

BAQ kaloMAX

8 Maintenance of the unit

8.1 Cleaning

When cleaning the kaloMAX, take care that no liquid is spilled into the inside of the unit. The
upper side is not completely sealed.

8.2 Replacement of the driving belt

If the driving belt has to be changed because of insufficient traction, this can be done without
opening the unit:
• Remove the cover of the left bearing.
• Remove the driving belt.
• Pass the new driving belt through the slot in the cover plate
and put it around the lower drive wheel (B).
• Put the driving belt around the drive wheel of the shaft(A).
The belt is guided over the inner side of the tension pulley (C).
• Attach the cover to the left bearing.

8.3 Fuses

Two 1 A delay-action fuses are placed in the power supply unit (double pole fuse protection).

8.4 Replacement of the driveshaft

If the traction rings on the driveshaft are damaged, it is best to replace the whole shaft,
because the tractions rings can only be trimmed for exact running when mounted on the shaft.
The cover of the left bearing has to be removed. After releasing the screws on both sides of
the driveshaft, the whole unit including the bearings can be pulled out to the left.

8.5 Replacement parts

Driving belt
O-Ring 85 x 3
Driveshaft
complete with trimmed traction rings, in exchange
Fuses
T 1 A
Manual
Order No.
50-113
50-112