InstallatIon and MaIntenance InstructIons
3 traNsport/storaGe
the valve is supplied with protective covers.
Do not remove the protective covers until
immediately prior to installation. they protect
the PfA surfaces from dust and mechanical
influences.
3.1 transport
- transport temperature -20°C to +65°C.
- Protect against external force (impact, shock,
vibration).
- Do not damage the coating.
4 features
4.1 General features
flange drillings Din 2501-1 Pn16
AnSi b16.5 Class 150
Other drillings (Pn25/40, AnSi Class 300) are available on request
body variants
Wafer type
flanged to Din standard
flanged to AnSi standard
bolted joint
A2 bolt quality for all bolts subjected to pressure
Adaptor variants bottle adaptor for glass threads to iSO gl32/45, customized threads
bottle cage for increased safety when sampling (breakage of the glass bottle)
needle adaptor for sampling with bottles which have a septum membrane
Outlet adaptor in various versions
bottle holder with spring action for various bottle sizes
Special adaptor for aseptic sampling
bayonet adaptor for sampling with a piston syringe (see neOJV-0021/VCiOm-01978)
Customized solutions are feasible
Operating element variants
Dead man's lever for hand operation
Pneumatic drive for full or semi-automatic operation
Piston syringe (the spindle is lifted by the plunger of the piston syringe,
see neOJV-0021/VCiOm-01978)
Weights
the values given in the following table are only approximate, as the weight can
vary additionally, because of the different adaptor and operating element variants
WeiGhts
dN
Nps
25
1
40
50
2
65
80
3
100
4
SAmPling VAlVe SV fOR SAmPling intO bOttleS
®
3.2 storage
- Storage temperature -20°C to +65°C, dry and
dust-free.
- A drying agent or heating is required in damp
storage areas to protect against condensation.
3.3 handling prior to installation
- Do not remove the protective caps until
immediately prior to installation.
- Protect against the effects of weather, such as
dampness (or else use a drying agent).
- Proper treatment prevents damage.
Weight compact design
4.0
5.1
6.1
8.7
10.0
13.7
Weight flanged face to face
6.5
8.7
10.6
16.0
18.0
20.0