3. SPECIFICATION

model no: ...................................................................bT2014
Rated battery voltage: ...................................................6/12V
charging system capability: ..................................... 12/24V**
Rating systems: ................................ DIN, EN, IEc, JIS, SAE
Test ranges:
.................................................................. 40-2100 ccA* EN
................................................................ 40-2000 ccA* SAE
................................................................. 30-1500 ccA* IEc
.................................................................. 25-1300ccA* DIN
.................................................................by battery type JIS
minimum power requirement: ..........................................1.5V
Voltage range: ............................................................1.5-30V
battery: ....................................................... 4 x AA (supplied)
consumables: ...............................bT2003.V2-01 printing roll
Note: *ccA - cold cranking Amps
** 24V alternator test

4. OPERATION

4.1.
connect the clamp lead.
4.2.

BEFORE TESTING

4.2.1.
before you test a battery in a vehicle, turn off the ignition, all accessories and loads. close all the vehicle doors and the boot/hatch.
4.2.2.
make sure you have put 4 AA 1.5V batteries into the battery chamber on the underside of the tester. Oxyride batteries are NOT
recommended because of the initial 1.7 Volt output. If the internal 1.5V batteries run out of power,the display will show "POWER
lOW". Replace AA 1.5V batteries before starting a new test.
4.2.3.
Note that nothing will be seen on the display until the tester is connected to a vehicle battery.
4.2.4.
make sure the battery terminals are clean. Wire brush them if necessary. connect the red clamp to the positive battery terminal
post; connect the black clamp to the negative battery terminal post.
4.2.5.
For the most accurate results, clamp on the lead part of the terminal only. Attaching to the clamp or fixture rather than directly on the
terminal will lead to unstable wrong test results.
4.2.6.
Paper load refer to fig.2
4.2.7.
a) Open the clear cover (a).
b) Place a new roll in the paper compartment (b).
c) Paper will be fed automatically when the tester senses a paper roll has been fitted.
1
Paper cover
2
Printer
3
Display
4
Directional keys
5
Enter key
© Jack Sealey limited
Fig.1
Original Language Version
Fig.2
bT2014 | Issue:1 01/06/17