Technical Specifications; Use And Maintenance Instructions; Operation - Wallgate PSH-23 Product Manual

Hand wash basin with integral tap
Table of Contents

Advertisement

Product Manual PSH-23

7. Technical Specifications

Table 1. Technical specifications
Weight
Dimensions
Water Supply
Waste connection
Optional Control Unit Specifications
Power supply
Power rating
Weight
Dimensions
Enclosure IP
Rating
Regulatory
compliance

8. Use and Maintenance Instructions

The PSH-23 water dispenser has been designed and manufactured from quality
materials. If these instructions are followed, the unit will give reliable efficient service.
The installer must pass these instructions to the customer.
8.1.

Operation

1. The unit is switched ON and OFF by the main isolation switch provided by the
installer and positioned in the maintenance duct adjacent to the electronic control
box. If a fault occurs with the unit then it must be switched OFF until the fault is
repaired by a qualified engineer.
Warning! Unqualified personnel must not remove the cover of the electronic
control box due to the risk of electric shock.
2. To use the basin, press the piezo touch buttons located on the front of the basin
that operate the flow of water. The button switch's do not have any moving parts
25 Kg
420mm (W) x 430mm (H) x 300mm (D)
Water pressure: 1 - 3 Bar (Dynamic) recommended.
Flow rate hand wash: 2LPM
Supply pipe size 15mm copper
40mm (1.5" pipe)
230V AC 50/60Hz 2 Amp single phase
Maximum power rating 60W
1.2 Kg
200mm (W) x 150mm (H) x 80mm (D)
IP53
Complies with RoHS, LVD 2014/35/EU and EMC
2014/30/EU directives.