Beninca Brain Operating Instructions Manual

Beninca Brain Operating Instructions Manual

Hide thumbs Also See for Brain:

Advertisement

L8542078
Rev. 05/06/03
Libro istruzioni
Operating instructions
Betriebsanleitung
Livret d'instructions
Manual de instrucciones
Książeczka z instrukcjami
CENTRALE DI COMANDO
CENTRALE DE COMMANDE
CENTRAL DE MANDO
CENTRALKA STEROWANIA
UNIONE NAZIONALE COSTRUTTORI
AUTOMATISMI PER CANCELLI, PORTE,
SERRANDE ED AFFINI
CONTROL UNIT
STEUEREINHEIT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Brain and is the answer not in the manual?

Questions and answers

Summary of Contents for Beninca Brain

  • Page 1 L8542078 Rev. 05/06/03 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE COMMANDE CENTRAL DE MANDO CENTRALKA STEROWANIA Libro istruzioni Operating instructions Betriebsanleitung UNIONE NAZIONALE COSTRUTTORI Livret d’instructions AUTOMATISMI PER CANCELLI, PORTE, Manual de instrucciones SERRANDE ED AFFINI Książeczka z instrukcjami...
  • Page 3 BRAIN control unit The BRAIN electronic control unit may be used for the control of 1 or 2 motors with power not higher than 500W+500W. GENERAL WARNINGS a) The electrical installation and the operating logic must comply with the regulations in force.
  • Page 4 Programming The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the desired values in the programming menus described below. The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer. The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
  • Page 5 Settable values MENU FUNCTION MEMO ON-OFF-(Default) Enables or disables automatic closing On: automatic closing enabled (ON) Off: automatic closing disabled Enables or disables condominium function. Off: condominium function disabled. (OFF) On: condominium function enabled. The step-by-step impulse or transmitter impulse has no effect during the opening phase. Enables or disables rapid closing On: rapid closing enabled.
  • Page 6 Settable values MENU FUNCTION MEMO ON-OFF-(Default) Select the 1/2 motors operating mode: On: only one motor (motor 1) active. Function to be used in the following cases: - for single motor, to connect M1:4-5-6. 1mot - for two syncronized motors (for instance overhead door), to connect M1:4-5-6 (OFF) and M2:7-8-9.
  • Page 7 Diagnostics In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and safety) can be displayed. One segment of the display is linked to each input. In the event of failure it switches on according to the following scheme. ����...
  • Page 8 � � � � � � ������� �� ������ ��� ������ ��� ����� � ������� ��� ���� �������� ��������� ���� ����� �� ��� �������� ���������� ��������� ��� ���� ���������� � ��������� �� ��� ���� ��� ���� �� ������� � ������� ��� ���� ��� ��� �� ���� ����� ��...

Table of Contents