Samsung AVXCSH022EE Service Manual page 39

Hide thumbs Also See for AVXCSH022EE:
Table of Contents

Advertisement

Product Specifications
Indoor Unit(cont.)
Wall Mounted type(Vivace)
Model
Power Supply
1)
Mode*
Cooling*
Capacity
Performance
Heating*
Condensate (with High fan speed)
Input
Power
Running Current
Sound Level
Sound Pressure (High/Low)*
Type
Model
Fan
Motor
Type
Output
Cooling (High)
Airflow Rate
Heating (High)
Type
Refrigerant
Control Method
Temperature Control
Safety Devices
Liquid (Flare)
Piping
Gas (Flare)
Connections
Drain
Net Weight
Weight
Shipping Weight
Net Dimensions (W x H x D)
Dimensions
Shipping Dimensions (W x H x D)
Auto Restart
Auto Swing
Functions
Group/Individual Control
External Contact Control
Trouble Shooting by LED
Installation Manual
Operation Manual
Pattern Sheet for Installation
Standard
Accessories
Flexible Drain Hose
Filter / Safety Grille
Wireless Remote Controller
Wireless Remote Controller
Simplified
Wired Remote
Standard
Optional
Controller
Accessories
Premium
External Contact Interface Module
EEV Kits
*1) Mode
- HP : Heat Pump, HR : Heat Recovery
*2) Nominal cooling capacities are based on;
- Indoor temperature : 27˚C DB, 19˚C WB
- Outdoor temperature : 35˚C DB, 24˚C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*3) Nominal heating capacities are based on;
- Indoor temperature : 20˚C DB, 15˚C WB
- Outdoor temperature : 7˚C DB, 6˚C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
*5) Specifications may be subject to change without prior notice for product improvement.
2-30
AVXWVH022E
AVXWVH028E
ND022VH
ø/V/Hz
1/220~240/50
HP / HR
kW
2.2
2)
Btu/h
7,500
kW
2.5
3)
Btu/h
8,500
Liters/h
1.40
W
30
A
0.16
4)
*5)
*5)
dB(A)
31
/ 21
-
Crossflow Fan
-
YDK-016S41408-01 YDK-016S41408-01 YDK-016S41408-01 YDK-016S41408-01 YDK-016S41408-01
-
Feedback SSR
W
-
3
*5)
m
/min
7.0
3
*5)
m
/min
7.3
-
R410A
-
EEV (Optional)
-
Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors
-
Fuse
ø, mm
6.35
ø, mm
12.7
ø, mm
ID 18 hose
kg
8.5
kg
11.5
mm
825x285x189
mm
900x349x252
-
O
-
O
-
O
-
O
-
O
-
O
-
O
-
X
-
O
-
Filter (Washable)
ARH-1364
-
MR-BH01
-
MWR-SH00
-
MWR-TH01
-
MWR-WS00
-
MIM-B14
MXD, MEV Series
AVXWVH036E
AVXWVH056E
ND028VH
ND036VH
ND056VH
1/220~240/50
1/220~240/50
1/220~240/50
HP / HR
HP / HR
2.8
3.6
9,500
12,200
3.2
4.0
10,900
13,600
1.44
1.91
30
35
0.16
0.18
31 / 21
35 / 21
Crossflow Fan
Crossflow Fan
Crossflow Fan
Feedback SSR
Feedback SSR
Feedback SSR
-
-
7
8.2
7.3
8.8
R410A
R410A
EEV (Optional)
EEV (Optional)
EEV (Optional)
Fuse
Fuse
6.35
6.35
12.7
12.7
ID 18 hose
ID 18 hose
8.5
8.5
11.5
11.5
825x285x189
825x285x189
1,065x298x218
900x349x252
900x349x252
1,137x377x299
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
O
O
Filter (Washable)
Filter (Washable)
Filter (Washable)
ARH-1364
ARH-1364
MR-BH01
MR-BH01
MWR-SH00
MWR-SH00
MWR-TH01
MWR-TH01
MWR-WS00
MWR-WS00
MIM-B14
MIM-B14
MXD, MEV Series
MXD, MEV Series
MXD, MEV Series
AVXWVH071E
ND071VH
1/220~240/50
HP / HR
HP / HR
5.6
6.8
19,100
23,200
6.3
7.0
21,400
23,800
3.03
3.51
50
50
0.27
0.30
40 / 30
41 / 30
Crossflow Fan
Feedback SSR
-
-
13.3
13.3
14
14
R410A
R410A
EEV (Optional)
Fuse
Fuse
6.35
9.52
12.7
15.88
ID 18 hose
ID 18 hose
12
12
15
15
1,065x298x218
1,137x377x299
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
O
O
Filter (Washable)
ARH-1364
ARH-1364
MR-BH01
MR-BH01
MWR-SH00
MWR-SH00
MWR-TH01
MWR-TH01
MWR-WS00
MWR-WS00
MIM-B14
MIM-B14
MXD, MEV Series
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avxcsh036eeNd0361hxeaAvxcsh028eeNd022hxseNd028hxseNd0361hxse ... Show all