Download Print this page

Makita 4076D Technical Information page 2

Cordless cleaner
Hide thumbs Also See for 4076D:

Advertisement

R
epair
CAUTION: Remove the battery from the machine for safety before repair/ maintenance
in accordance with the instruction manual!
[1] DISASSEMBLY/ASSEMBLY
[1] -1. Front cover complete
DISASSEMBLING
Take the following step. ( Fig. 1)
Fig. 1
Raise Front lever by pushing its far
side from Inlet.
far side of Front lever
Inlet
from Inlet
Note: Do not raise Front lever strongly.
ASSEMBLING
Fit Seal to Front cover. And then assemble Front cover to Housing set. (Fig. 2)
Fig. 2
Front cover
Insert the hook of Front cover into
the slit of Housing set. And then
assemble Front cover to Housing set.
Remove Front cover by pulling toward
the direction designated with black arrow.
Front cover
Seal
Slit
Remove Seal from Front cover.
Front cover
Note: Assemble Seal to Front cover
so that the groove portion faces
Housing set side
Cross section of Seal
Housing set is sealed
with the lip portion.
Housing set
P 2/ 6
Seal

Advertisement

loading