Closed loop controller
Table of Contents

Advertisement

Pin Name
Pin #
21
Digital Input:
Reset Leak
Alarm
[DI_4]
2
35
Digital Input:
Leak Detect
Input
[DI_5]
17
5
Digital Input:
Left Proximity
Sensor/
Counter
[DI_6]
31
20
Digital Input:
Right
Proximity
Sensor
[DI_7]
1
26
Digital Output:
Line Pressure
Control Status
[DO_0]
44
40
Digital Output:
Flow Rate
Control Status
[DO_1]
14
Digital Output:
10
Supply
Pressure
Status
29
[DO_2]
27
Wire Color
Designation
Brown/
Reference High VDC
Black Stripe
White
Reference Low VDC
Pink/
Reference High VDC
Red Stripe
Violet/
Reference Low VDC
Black Stripe
Violet
Reference High VDC
Blue/
Reference Low VDC
White Stripe
Blue/
Reference High VDC
Black Stripe
Black
Reference Low VDC
Sink: Connect To
Orange/
ground when
White Stripe
closed
Source: Connect
Light Green/
to power when
Green Stripe
closed
Sink: Connect To
Red/
ground when
Green Stripe
closed
Source: Connect
White/
to power when
Black Stripe
closed
Sink: Connect To
Light Blue
ground when
closed
Source: Connect
Brown/
to power when
White Stripe
closed
Levels
24 V = Not Active
0 V = Active
0 V = Not Active
24 V = Active
24 V = Not Active
0 V = Active
0 V = Not Active
24 V = Active
24 V = Not Active
0 V = Active
0 V = Not Active
24 V = Active
24 V = Not Active
0 V = Active
0 V = Not Active
24 V = Active
Relay Open = Not
Active
Relay Closed = Active
Relay Open = Not
Active
Relay Closed = Active
Relay Open = Not
Active
Relay Closed = Active
Relay Open = Not
Active
Relay Closed = Active
Relay Open = Not
Active
Relay Closed = Active
Relay Open = Not
Active
Relay Closed = Active
Note
Once a leak has been detected
by the system, the controller
will shut off the pump. This
digital port is used to
deactivate the leak alarm so
that normal pump operation
can continue.
Send leak detect inputs into
this digital port
If operating a pump with end
stroke detection instead of a
shuttle operated pump the left
and right proximity sensor
inputs need to be connected to
these digital ports. The left
proximity switch input will be
used to count cycles.
For those using a shuttle pump
and want the controller to
preform cycle counting, then a
pressure switch can be
connected to the pump. See
pump's owner's manual for
details.
These digital outputs have been
designated to notify the user
which mode the controller is
operating in. If none are on,
then the controller has been
turned off.
Manual version 1.0.2