Also available; specify when ordering: 
● Voltage​ : 120/208/240  
● Amps​ : 12.5/11.1/16.5 
● Watts​ : 1500/2300/1500 
 
Includes: 72" cord and NEMA approved plug. 
 
Shipping Weight: 
200lbs. (91kg.) – DP1350 
 
 
S A F E T Y S U M M A R Y 
 
Warning 
In case of power cord damage, do not 
attempt to repair or replace the power cord. 
Please contact the manufacturer or the local 
distributor.  
 
Avoid touching hot surfaces while operating 
the machine. 
 
Caution 
During normal operation, the base of the 
machine must be installed or placed above 
the wall socket. 
 
When servicing or cleaning the machine, 
make sure that the power cord is removed 
from the wall socket. 
 
 
O P E R A T I O N T E M P E R A T U R E 
& T I M E R C O N T R O L
 
 
Solid State Controller 
This controller has three (3) control features: 
1. ​ T emperature​ – May be set from 
100°-425°F (38°-163°C) 
 
2. ​ T ime​ – Time may be set from 1 second to 
10 minutes. 
 
3. ​ C ounter​ – Cycle counter counts the 
number of applications from 1 to 9999 (see 
additional Notes – Counter). 
 
4. ​ " 2 Lower"​ (Fig. A) Refers to models using 
upper and lower heated surfaces. 
 
 
Controller Operation 
1. ​ V iewing the Modes of Operation​ :  
To view the set points of temperature, timer 
and counter, press MODE button to view the 
desired mode of operation. 
 
2. ​ C hanging Temperature: 
Press MODE button until temperature is 
displayed. 
 
Press and hold SET button while pressing the 
UP (↑) and DOWN (↓) arrow buttons to 
desired temperature setting. 
 
3. ​ C hanging Time: 
Press MODE button until time is displayed. 
 