CONTENTS Introduction Description General Do’s and Don’ts Controls Operating the Lift Emergency procedures Maintenance & Servicing Fault finding Safety feature checks Service history record Declaration of conformity Lift specification...
Thank you for choosing the Terry 1100W TSL1 lift, designed and manufactured in the U.K. using the latest technology from Terry Group Ltd. We want you to get the most out of your 1100W TSL1 Lift and to help in this aim, we have produced this small booklet on operation and maintenance of the equipment which we trust you will find helpful.
Page 5
Platform controls Power pack Ground ramp Control Post It is most important that before operating the lift you read these instructions fully and are familiar with the controls and operating procedure. Our policy is one of continous product development and the Company reserves the right to change specification without notice.
GENERAL DO’S AND DON’TS • Always leave the power supply to the lift switched on, even when you go away. The lift control circuits are fed by a battery, which must be kept constantly charging. • Never allow children to play on or around the lift. •...
CONTROLS Location • Lower level control switch(standard installation)-mounted on control post. • Lower level control switch (pit installation / side entry) mounted on the building structure at the lower level. • Platform control switch-mounted on lift the car control panel. •...
OPERATING THE LIFT If the radio control enabler option is fitted press the key fob to activate the control stations. The lift can be called by maintaining pressure on the call button and waiting for it to stop at the appropriate level. Move on to the platform and apply the wheelchair brakes.
EMERGENCY PROCEDURES a) Isolation of the lift is achieved by switching the key switch on the car control panel or by switching off the isolator switch on the charger pack located indoors. b) In the unlikely event that the lift stops part-way through its travel and will not restart, it can be lowered manually.
MAINTENANCE & SERVICING Provided the operating instructions are observed the lift will give many years of trouble free service. It is designed for outdoor use (but not for coastal applications). Dependent on frequency of use, this lifting platform should be serviced at least every 6 months. This service should be conducted by competent persons trained in the service and repair of the product.
FAULT FINDING The table below should help solve any problems, which may be stopping your lift from operating correctly. If, however, your lift still does not operate correctly after referring to this table please do not hesitate to call the number on the back of this booklet for further advice.
SAFETY FEATURE CHECKS As a precautionary measure it is advised that you check the safety features built into the lift on a weekly basis. Carry out the ckecks as discribed below: - • Platform safe edge - With the lift at the upper level call the lift down and once it is moving obstruct the platform safe edge, the lift should stop.
DECLARATION OF CONFORMITY Lift Type: 1100W TSL1 This lift was manufactured by TERRY GROUP Ltd., who declare that this lift fulfils all the relevant provisions of the following Directives: 2004/108/EEC EMC Specifications 2006/42/EC Machinery Directive This lift also fulfils all the relevant provisions of the following...
LIFT SPECIFICATION Address of manufacturer: Terry Group Ltd. Unit 1 Longridge Trading Estate Knutsford, Cheshire, England WA16 8PR Lift serial No. Year of manufacture Maximum load 385Kg Maximum travel 1 metre Power supply 240V AC ~ 50/60 Hz Control voltage...
Page 16
This 1100 W TSL1 has been supplied by: 10250c...
Need help?
Do you have a question about the 1100W TSL1 and is the answer not in the manual?
Questions and answers