Page 1
Germany | Switzerland | Austria Benelux France Sweden USA | Canada Other Countries Althen GmbH Mess- & Sensortechnik Althen bv Sensors & Controls Althen / DB Innovation Althen Sensors & Control AB Altheris Inc Sensors & Controls Inc. please contact us...
Content 1 General Information ........................... 3 1.1 Safety Instructions ........................3 1.2 Qualified Personnel ........................3 1.3 Intended Use ..........................3 2 Instructions for use of the measuring amplifier ..............4 3 Technical Description ........................5 4 Terminal Assignment........................5 4.1 Supply Voltage ..........................
To ensure reliable and safe operation, the measuring amplifier must be operated in compliance with the specifications according to this technical description only. These regulations must also be observed if accessories, which have been ordered from Althen Mess- & Sensortechnik GmbH together with the measuring amplifier, are being used.
Notice: Changes of the measuring system of any kind demand for the explicit approval of Althen Mess- & Sensortechnik GmbH. Changes of any kind done without that approval exclude all possible warranty and/or liability of Althen Mess- & Sensortechnik GmbH.
3 Technical Description This single axis, industrial tilt measuring system, which consists of one none-contact sensor and an electronic customized for said sensor, serves to measure accurate tilt angles in x-axis and it is intended for side wall mounting. Depending on the version the tilt angle can be between ± 3 up to ± 60°, or between 0 …...
Before mounting, all transport protection has to be removed and disposed of properly. The measuring object is to be leveled horizontally (e.g. using the PRO3600 protractor from ALTHEN). The sensor is to be mounted to a vertical surface at the object to measure.
5.1 Calibration of the tilt measuring system Notice: The measuring system is factory pre-calibrated. Under normal circumstances, an adjustment is not necessary. After mounting the system, caused by deviations of mounting, a slight correction of the zero-point is often necessary. The calibration of the span / full-scale is to be checked. 5.1.1 Adjusting the zero-point - Connect an amperemeter ■...
Amplifiers and measurement units manufactured and sold by Althen Mess- & Sensortechnik GmbH serve B2B purposes only. Therefore, those old appliances must not be given to the communal disposer, but must be given back to the seller or disposed of properly.
Appendix Datasheet Number of measuring axis: Supply voltage: 18…28 VDC Protected against voltage reversal Power consumption: ca. 3 W Analogue output 4 … 20 mA (2-wire) Max. impedance depending on voltage Frequency (-3dB): 0,5 Hz ±3°, ±5°, ±10°, ±15, ± 20, ±30, ±45° Preferred measuring ranges Other ranges on request 0…10°, 0…30°, 0…45°, 0…60°, 0…90°...
EMC-Mounting Enclosure with high- frequency-seal Keep enclosure closed EMI-/RFI-approved To improve the noise- cable lead-through Use with cable Connect screen to immunity feed the leads connect to screen screen ground with through ferrite-rings ground-clamp Amplifier/Sensor Grounding case: Case need to be mounted on a grounded surface! Step...
Page 12
Subject to modifications. All information describe our products in general form. 12 | 12...
Need help?
Do you have a question about the NM1-IP-2L-420-B05 and is the answer not in the manual?
Questions and answers