Installation & Startup; Safety Precautions - Viking GCV12 Series Use & Installation Manual

Under-counter micro green & herb cabinet
Table of Contents

Advertisement

WARNING:
Risk of personal injury
IMPORTANT:
Power cord is 6' long
CAUTION: Electrical Shock
Hazard
IMPORTANT: FILTERED
WATER REQUIRED
IMPORTANT:
Not under warranty
This appliance is equipped with a cord having a grounding wire with a grounding plug which must be hard wired or
plugged into an outlet that is properly installed and grounded. In the event of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape wire for the electric current.
LOCATION
WARNING—Improper use of the grounding can result in a risk of electric shock. Consult a qualified electrician or ser-
vice agent if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is
properly grounded.

Place the cabinet on level ground so that the inside water flows evenly. Adjust the leveling legs so that they are on the
floor. If your floor is not level, adjust the legs so that the unit is level. NOTE: Unit must be level in order to function
properly.

See CUTOUT DIMENSIONS ON NEXT PAGE

Leave at least 19 inches (483 mm) at the front of the cabinet, so there is ample space for opening the doors and pulling
the drawers out.

Connect city water supply and city drain to the 3/8" NPT female fittings at the back of the unit . Access to the
connections will be at the back of the cabinet. NOTE: This unit is to be installed with adequate backflow protection
to comply with all applicable federal, state and local codes.

City water connection must not be further than 10 feet from the cabinet and no higher than 6 feet from the
connections. A minimum of 35 PSI is required to feed the cabinet.

Install the lights and diffuser panels (instructions on page 20)

The 120V electrical outlet should be within 6 feet of the cabinet. Do not use an extension cord. Connect to a properly
grounded outlet according the electrical specifications for the cabinet. See page 3 for specifications.
Pipes that have not been in regular use should be cleaned an flushed
with running water prior to connecting to cabinet
Make sure the water inlet hose and drain hose are not twisted, crushed,
entangled or leaking. Do not use connection hoses that have been used
previously for other appliances.
If the unit is built in to a wall or structure, make sure that it can
be easily moved for access to the back and side panels for
service and maintenance.

SAFETY PRECAUTIONS

Installation procedures must be performed by a qualified technician with full
knowledge of all applicable electrical and plumbing codes. Failure could result
in personal injury and property damage.
If necessary, contact a licensed electrician to install an appropriate 15 amp
electrical circuit with correct NEMA receptacle. Ensure that the plug is accessi-
DO NOT use an extension cord.
ble after installation.
The ground prong of the power cord is part of a system designed to protect
you from electric shock in the event of internal damage.
DO NOT cut off the large round ground prong or twist a blade to fit an exist-
ing receptacle.
Due to varying water quality in different municipalities, make sure that your
facility water is filtered of sediment and chemicals before hooking up the fill
lines. Sediment from hard and/or softened water may eventually clog up the
pumps and filters.
Damage to unit due to being connected to the wrong voltage or phase is NOT
covered by warranty.
GROUNDING INSTRUCTIONS
INSTALLATION AND STARTUP
LOCATION AND INSTALLATION
6
City DRAIN connection:
City FILL connection:
3/8" NPT female fitting
3/8" NPT female fitting