Focon Showtechnic Expolite Tour-Stick Neo 4 XAL User Manual page 33

Table of Contents

Advertisement

Available languages

Available languages

Miscellaneous Settings
MENU
PERSON
SETTING
The default password is: UP - DOWN - UP - DOWN - ENTER
UPLOAD: sends the user programs to connected slave fixtures.
RESET: sets all editable settings back to factory default.
COLOR: in this submenu a colour calibration is selected or deactivated. When RGBW is
selected, the maximum brightness values at DMX = 255 are limited to the values set in CALIB.CCT.
When UC is selected the Uniform-Colour factory calibration is used, which adjusts devices of
different generations. If the value is set OFF, the calibration is deactivated and the device reaches
the maximum brightness.
DIMMER: controls different dim curves to simulate a halogen bulb (DIM4/DIM3/DIM2/DIM1/OFF).
DMX ERROR: sets how the fixture responses if DMX-signal gets lost. Set SAVE to hold the last
received value or BLACK for blackout.
PWM: gives the user the possibility to adjust the PWM frequency of the leds
(1200HZ/2400HZ/4000HZ/6000HZ/25000HZ).
FULL POWER CCT: sets the colour temperature at maximum output. 3200K/4200K/5600K/10000K
and NORMAL can be set.
UPLOAD
****
RESET
COLOR
DIMMER
DMX ERROR
PWM
FULL POWER CCT
E-33
SEND
****
****
UC
OFF
RGBW
DIM4
DIM3
DIM2
DIM1
OFF
SAVE
BLACK
1200HZ
2400HZ
4000HZ
6000HZ
25000HZ
3200K
4200K
5600K
10000K
NORMAL